| Total | Frontend | Backend | SimCode | Templates | Compilation | Simulation | Verification |
|---|---|---|---|---|---|---|---|
| 1606 | 1511 | 1510 | 1510 | 1502 | 1502 | 1371 | 1245 |
Test started: 2025-11-30 06:00:53
Total time taken: 19:28:22
System info: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 22.04.5 LTS
OpenModelica Version: OMCompiler v1.24.5-v1.24.5.1+gb17346080d
FMI tool: b"warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input\nOMSimulator v3.0.0.post119-gef71d82-linux-debug\ninfo: 1 warnings\ninfo: 0 errors"
FMI version: 2.0
OpenModelicaLibraryTesting Changes| Commit | Date | Author | Summary |
|---|---|---|---|
| e46ee83 | 2025-11-28 10:03:55 +0100 | Francesco Casella | Update compilation parameters for BaseModelica.jl testing (#258) |
Tested Library: Buildings_11 11.1.1 warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input OMSimulator v3.0.0.post119-gef71d82-linux-debug info: 1 warnings info: 0 errors
{
"convertFromVersion": [
"8.0.0",
"8.1.0",
"8.1.1",
"8.1.2",
"8.1.3",
"9.0.0",
"9.1.0",
"9.1.1",
"9.1.2",
"10.0.0",
"10.1.0"
],
"path": "Buildings",
"provides": [
"11.0.0",
"11.1.0",
"11.1.0"
],
"support": "noSupport",
"uses": {
"Modelica": "4.0.0"
},
"version": "11.1.1-maint.11.x",
"zipfile": "https://github.com/lbl-srg/modelica-buildings/archive/7d4ef2182609d3e1967660715751f62a0f2534c2.zip"
}
BuildModel time limit: 300s
Simulation time limit: 400s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default
Reference Files: /mnt/ReferenceFiles/Buildings/csv/maint_11.x
commit 7d4ef2182609d3e1967660715751f62a0f2534c2 Author: Michael WetterVerified using: OpenModelica 1.25.0~dev-371-g1c5c528 (diffSimulationResults)
Flags:setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config: {
"ignoreModelPrefix": [
"Buildings.Utilities.IO.BCVTB.Examples",
"Buildings.Obsolete"
],
"library": "Buildings",
"libraryVersion": "maint.11.x",
"libraryVersionNameForTests": "11",
"referenceFileExtension": "csv",
"referenceFileNameDelimiter": "_",
"referenceFiles": "/mnt/ReferenceFiles/Buildings/csv/maint_11.x",
"runOnceBeforeTesting": [
[
"$resourceLocation/src/ThermalZones/install.py",
"--binaries-for-os-only"
]
],
"ulimitExe": 400,
"ulimitOmc": 300
}
Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.