/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms_res.mat --tempDir=temp_Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms/model-s1yrhxhx" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.fmu - startTime: 0.000000 - stopTime: 7200.000000 - tolerance: 0.000001 - stepSize: 2.880000 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 2.880000 info: Result file: Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms_res.mat (bufferSize=1) info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.ala.assMes2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.ala.assMes3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.ala.assMes4.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.ala.assMes5.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 4350.000000 | | | | ((not ala.truDel5.y)) --> "Warning: the hot-duct damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 4350.000000 | | | | ((not ala.truDel3.y)) --> "Warning: the cold-duct damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 6225.000001 | | | | ((not ala.truDel4.y)) --> "Warning: hot-duct airflow sensor should be calibrated." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 6225.000001 | | | | ((not ala.truDel2.y)) --> "Warning: cold-duct airflow sensor should be calibrated." info: Final Statistics for 'model.root': NumSteps = 343 NumRhsEvals = 344 NumLinSolvSetups = 21 NumNonlinSolvIters = 343 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors