/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.DHC.Plants.Steam.BaseClasses.Examples.ControlVolumeEvaporation_res.mat --tempDir=temp_Buildings_11_Buildings_DHC_Plants_Steam_BaseClasses_Examples_ControlVolumeEvaporation_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_DHC_Plants_Steam_BaseClasses_Examples_ControlVolumeEvaporation.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Steam.BaseClasses.Examples.ControlVolumeEvaporation" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Steam.BaseClasses.Examples.ControlVolumeEvaporation" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Steam.BaseClasses.Examples.ControlVolumeEvaporation/model-m6m79tdw" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_DHC_Plants_Steam_BaseClasses_Examples_ControlVolumeEvaporation.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.000400 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Steam.BaseClasses.Examples.ControlVolumeEvaporation/model-m6m79tdw/temp/0001_Buildings_11_Buildings_DHC_Plants_Steam_BaseClasses_Examples_ControlVolumeEvaporation/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Media/Water/IF97_Utilities.mo:2900: IF97 medium function tsat called with too low pressure p = 0 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Steam.BaseClasses.Examples.ControlVolumeEvaporation/model-m6m79tdw/temp/0001_Buildings_11_Buildings_DHC_Plants_Steam_BaseClasses_Examples_ControlVolumeEvaporation/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_11_Buildings_DHC_Plants_Steam_BaseClasses_Examples_ControlVolumeEvaporation" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors