/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.DHC.ETS.Combined.Subsystems.Validation.SwitchBox_res.mat --tempDir=temp_Buildings_11_Buildings_DHC_ETS_Combined_Subsystems_Validation_SwitchBox_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_DHC_ETS_Combined_Subsystems_Validation_SwitchBox.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Combined.Subsystems.Validation.SwitchBox" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Combined.Subsystems.Validation.SwitchBox" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.ETS.Combined.Subsystems.Validation.SwitchBox/model-x3324i2y" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_DHC_ETS_Combined_Subsystems_Validation_SwitchBox.fmu - startTime: 0.000000 - stopTime: 1000.000000 - tolerance: 0.000001 - stepSize: 0.400000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pum2.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum2.eff.yMot, has value: -0.155738" info: maximum step size for 'model.root': 0.400000 info: Result file: Buildings_11_Buildings.DHC.ETS.Combined.Subsystems.Validation.SwitchBox_res.mat (bufferSize=1) info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Subsystems_Validation_SwitchBox.setMasFlo2.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_DHC_ETS_Combined_Subsystems_Validation_SwitchBox.setMasFlo2.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 127 NumRhsEvals = 128 NumLinSolvSetups = 10 NumNonlinSolvIters = 127 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors