/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop_res.mat --tempDir=temp_Buildings_11_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_OpenLoop_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_OpenLoop.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop/model-tqi2n1yq" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_OpenLoop.fmu - startTime: 0.000000 - stopTime: 1000.000000 - tolerance: 0.000001 - stepSize: 0.400000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Media/package.mo:5869:7-5869:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ahu.sta_b1.p >= 0.0 and ahu.sta_b1.p <= 1e8)) --> "Variable violating min/max constraint: 0.0 <= ahu.sta_b1.p <= 1e8, has value: -2.83992e+06" info: maximum step size for 'model.root': 0.400000 info: Result file: Buildings_11_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 704 NumRhsEvals = 706 NumLinSolvSetups = 39 NumNonlinSolvIters = 705 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors