TransiEnt test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
400 328 308 308 298 279 227 0

Test started: 2024-03-16 04:23:13
Total time taken: 2:13:54
System info: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 22.04.3 LTS

OpenModelica Version: OMCompiler v1.23.0-dev.378+g063c0d3760

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
c36be382024-03-13 14:20:22 +0100Francesco CasellaRemoved Buildings 8.1.x from the library testing (#77)

Tested Library: TransiEnt 2.0.2

{
 "convertFromVersion": [
  "0.3.0",
  "1.0.1",
  "1.1.0",
  "1.2.0",
  "1.3.0",
  "1.3.1",
  "2.0.0"
 ],
 "path": "TransiEnt 2.0.2-dev",
 "sha": "9c0bd25f9ed0ee6ebf0ed0504e1b6ec18f8682e0",
 "support": "noSupport",
 "uses": {
  "Buildings": "9.0.0",
  "ClaRa": "1.8.0",
  "DataFiles": "1.0.5",
  "Design": "1.0.7",
  "DymolaCommands": "1.11.0",
  "Modelica": "4.0.0",
  "ModelicaReference": "4.0.0",
  "Modelica_LinearSystems2": "2.4.0",
  "Modelica_StateGraph2": "2.1.0",
  "TILMedia": "1.8.0-ClaRa"
 },
 "version": "2.0.2-master",
 "zipfile": "https://github.com/adrpo/transient-lib/archive/9c0bd25f9ed0ee6ebf0ed0504e1b6ec18f8682e0.zip"
}

BuildModel time limit: 660s
Simulation time limit: 480s
Default tolerance: 1e-06
Optimization level: Tool default

Flags:
setCommandLineOptions("-d=newInst,-frontEndUnitCheck")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
setCommandLineOptions("--allowNonStandardModelica=nonStdEnumerationAsIntegers,nonStdTopLevelOuter")
setEnvironmentVar("publicData", "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/")
setEnvironmentVar("privateData", "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/")
setEnvironmentVar("superstructureTables", "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/")
setEnvironmentVar("superstructureInput", "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/")
Config:
{
 "environmentSimulation": [
  [
   "publicData",
   "$libraryLocation/Tables/"
  ],
  [
   "privateData",
   "$libraryLocation/Tables/"
  ],
  [
   "superstructureTables",
   "$libraryLocation/Tables/superstructure/Tables/"
  ],
  [
   "superstructureInput",
   "$libraryLocation/Tables/superstructure/RegionInformation/"
  ]
 ],
 "extraCustomCommands": [
  "setCommandLineOptions(\"--allowNonStandardModelica=nonStdEnumerationAsIntegers,nonStdTopLevelOuter\")",
  "setEnvironmentVar(\"publicData\", \"$libraryLocation/Tables/\")",
  "setEnvironmentVar(\"privateData\", \"$libraryLocation/Tables/\")",
  "setEnvironmentVar(\"superstructureTables\", \"$libraryLocation/Tables/superstructure/Tables/\")",
  "setEnvironmentVar(\"superstructureInput\", \"$libraryLocation/Tables/superstructure/RegionInformation/\")"
 ],
 "library": "TransiEnt",
 "libraryVersion": "master",
 "libraryVersionNameForTests": ""
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
TransiEnt.Basics.Adapters.Check.TestEPP_to_QS (sim) 0.123.3515.490.760.060.020.052.4519.73
TransiEnt.Basics.Adapters.Check.TestRealGasAdapters (sim) 0.6435.8215.193.245.290.582.1824.5352.22
TransiEnt.Basics.Blocks.Check.CheckDoubleSetpointController (sim) 0.022.6315.060.520.010.010.022.0718.39
TransiEnt.Basics.Blocks.Check.CompareSlewRateLimiters (sim) 0.022.6113.080.480.020.010.022.0916.33
TransiEnt.Basics.Blocks.Check.TestDeadZoneLinear (sim) 0.022.5113.400.500.030.010.021.9516.55
TransiEnt.Basics.Blocks.Check.TestDelayedBooleanReplicator (sim) 0.012.5413.030.540.010.010.031.9516.12
TransiEnt.Basics.Blocks.Check.TestDiscreteTimeSlewRateLimiter (sim) 0.022.4712.910.470.010.000.021.9615.93
TransiEnt.Basics.Blocks.Check.TestDiscretizePrediction (sim) 0.022.4913.010.470.040.010.021.9416.05
TransiEnt.Basics.Blocks.Check.TestHysteresis_inputVariable (sim) 0.022.6312.990.490.010.000.022.1216.17
TransiEnt.Basics.Blocks.Check.TestOnOffRelay (sim) 0.033.1412.890.570.060.020.052.4316.64
TransiEnt.Basics.Blocks.Check.TestPIDControllers (sim) 0.022.8913.010.520.070.010.042.2416.44
TransiEnt.Basics.Blocks.Check.TestPITrigger (sim) 0.022.5913.200.520.020.010.022.0316.35
TransiEnt.Basics.Blocks.Check.TestRealVectorExpression (sim) 0.022.4713.110.540.010.010.021.9016.14
TransiEnt.Basics.Blocks.Check.TestSawTooth (sim) 0.012.4913.130.510.010.000.021.9516.16
TransiEnt.Basics.Blocks.Check.TestSlewRateLimiter (sim) 0.093.0213.060.640.050.020.052.2716.71
TransiEnt.Basics.Blocks.Check.TestSlewRateLimiterStep (sim) 0.083.1513.320.670.070.020.062.3317.13
TransiEnt.Basics.Blocks.Check.TestSplineLim (sim) 0.022.4813.200.520.020.010.021.9216.25
TransiEnt.Basics.Blocks.Check.TestSwitchAtTimeOfDay (sim) 0.022.6413.560.550.010.000.022.0616.79
TransiEnt.Basics.Blocks.Check.TestSwitchRamp (sim) 0.022.7312.810.490.020.010.032.1916.10
TransiEnt.Basics.Blocks.Check.TestTimers (sim) 0.012.4912.670.520.010.000.021.9415.73
TransiEnt.Basics.Blocks.Check.TestTrumpetCurves (sim) 0.022.3713.050.460.010.000.021.8815.99
TransiEnt.Basics.Blocks.Check.TestVariousSlewRateLimiter (sim) 0.082.9412.860.530.050.020.052.3016.40
TransiEnt.Basics.Blocks.Check.TestWeekendPulse (sim) 0.052.5612.990.520.010.010.022.0016.11
TransiEnt.Basics.Blocks.SwitchAtTimeOfDay (sim) 0.022.5513.410.510.010.000.022.0116.59
TransiEnt.Basics.Functions.GasProperties.Check.TestGCVCalculation 0.000.9513.660.680.140.030.100.0015.34
TransiEnt.Basics.Functions.GasProperties.Check.TestNCVCalculation 0.000.8513.610.620.120.030.080.0015.18
TransiEnt.Basics.Media.Gases.Check.TestMediaRecords (sim) 0.287.9413.600.642.120.060.125.0022.42
TransiEnt.Basics.Media.Gases.Check.TestRhoCalculationH2NG7 (sim) 0.234.1213.900.630.100.020.103.2819.39
TransiEnt.Basics.Tables.Ambient.UndergroundTemperature_Duesseldorf_1m_3600s_TMY (sim) 0.082.8813.350.560.040.010.052.2216.94
TransiEnt.Basics.Tables.Check.TestGenericCombiTable1DS (sim) 0.082.8013.170.550.040.020.052.1516.65
TransiEnt.Basics.Tables.Check.TestGenericCombiTable2D (sim) 0.082.8713.310.490.040.020.052.2816.80
TransiEnt.Basics.Tables.Check.TestGenericDataTable (sim) 0.162.9513.420.570.040.020.052.2817.10
TransiEnt.Components.Boundaries.Ambient.Check.TestAmbientConditions (sim) 0.113.6912.860.600.070.020.072.9317.31
TransiEnt.Components.Boundaries.Ambient.Check.TestUndergroundTemperature (sim) 0.092.8812.900.490.040.010.052.2916.48
TransiEnt.Components.Boundaries.FluidFlow.Check.TestBoundaryVLE_Txim_flow (sim) 0.133.6213.570.640.110.030.082.7517.96
TransiEnt.Components.Boundaries.FluidFlow.Check.TestBoundaryVLE_hxim_flow (sim) 0.113.8513.230.680.100.030.072.9717.80
TransiEnt.Components.Boundaries.FluidFlow.Check.TestBoundaryVLE_pTxi (sim) 0.113.6013.690.620.080.030.072.8118.51
TransiEnt.Components.Boundaries.FluidFlow.Check.TestBoundaryVLE_phxi (sim) 0.113.6013.520.580.070.020.072.8417.88
TransiEnt.Components.Boundaries.Gas.Check.CheckStepVariationModels 0.000.6813.010.570.050.020.050.0014.45
TransiEnt.Components.Boundaries.Heat.Check.Test_HeatflowExternal_L2 (sim) 0.096.6313.560.740.201.880.153.6620.83
TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrMFlow (sim) 0.105.8913.400.720.130.041.913.1120.00
TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow (sim) 0.105.7913.630.720.130.041.932.9720.08
TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L2 (sim) 0.156.8613.820.730.192.020.203.7321.45
TransiEnt.Components.Boundaries.Statistical.Check.TestGwpEmissions (sim) 0.083.9213.890.560.070.020.682.5919.44
TransiEnt.Components.Electrical.FuelCellSystems.Check.TestFuelCellSystem_SOFC (sim) 0.3910.8614.310.753.220.110.825.9730.12
TransiEnt.Components.Electrical.FuelCellSystems.FuelCell.Check.TestPEM (sim) 0.267.7914.320.682.360.070.144.5424.14
TransiEnt.Components.Electrical.FuelCellSystems.FuelCell.Check.TestSOFC (sim) 0.188.2114.380.692.240.051.104.1324.34
TransiEnt.Components.Electrical.FuelCellSystems.SteamReformer.Check.TestSteamReformer (sim) 0.157.3414.430.670.231.700.993.7523.56
TransiEnt.Components.Electrical.Grid.Check.CheckElectricBusbarComplex 0.002.1713.460.671.510.000.000.0016.39
TransiEnt.Components.Electrical.Grid.Check.TestSeparableLine (sim) 0.116.3814.350.721.680.050.433.5022.89
TransiEnt.Components.Electrical.Machines.Check.CheckActivePowerGenerator (sim) 0.174.1013.740.590.070.020.083.3323.01
TransiEnt.Components.Electrical.Machines.Check.CheckInductionMotorSimple (sim) 0.093.2913.460.600.100.030.082.4917.76
TransiEnt.Components.Electrical.Machines.Check.CheckInductionMotor_L1E (sim) 0.213.7113.150.610.120.030.072.8818.18
TransiEnt.Components.Electrical.Machines.Check.CheckInductionMotor_L3E (sim) 0.263.7713.430.600.150.030.082.9118.41
TransiEnt.Components.Electrical.Machines.Check.CheckLinearSynchronousMachine (sim) 0.184.7713.860.550.080.020.723.4122.72
TransiEnt.Components.Electrical.Machines.Check.CheckLinearSynchronousMachineComplex (sim) 0.166.3412.780.511.670.040.243.8822.77
TransiEnt.Components.Electrical.Machines.Check.CheckMSLSynchronousMachine (sim) 0.705.9413.750.600.170.031.443.6923.59
TransiEnt.Components.Electrical.Machines.Check.CheckSynchronousMachineComplex (sim) 0.417.6212.750.521.720.050.654.6822.62
TransiEnt.Components.Electrical.Machines.Check.CheckTwoAxisSynchronousMachineComplex (sim) 0.267.8414.050.722.230.060.174.6624.12
TransiEnt.Components.Electrical.Machines.Check.CheckTwoAxisSynchronousMachineComplexSubtransient (sim) 0.567.9213.530.692.280.060.184.7123.13
TransiEnt.Components.Electrical.Machines.Check.CheckTwoAxisSynchronousMachineComplexTransient (sim) 0.297.8913.680.662.220.060.174.7923.90
TransiEnt.Components.Electrical.Machines.ExcitationSystemsVoltageController.Check.CheckACExciter (sim) 1.099.1213.700.672.410.070.365.6027.25
TransiEnt.Components.Electrical.Machines.ExcitationSystemsVoltageController.Check.CheckDCExciter (sim) 0.399.7812.500.642.350.070.576.1529.52
TransiEnt.Components.Electrical.Machines.ExcitationSystemsVoltageController.Check.CheckSimpleExcitationSystem (sim) 0.208.2113.130.592.050.070.175.3323.83
TransiEnt.Components.Electrical.Machines.ExcitationSystemsVoltageController.Check.GridN5AreaVoltageCollapseOEL 0.006.8213.240.912.740.180.962.0424.63
TransiEnt.Components.Electrical.Machines.MSLSynchronousMachine 0.000.5713.160.510.060.000.000.0014.35
TransiEnt.Components.Electrical.PowerTransformation.Check.CheckIdealTriac (sim) 0.092.9013.390.470.070.020.062.2816.90
TransiEnt.Components.Electrical.PowerTransformation.Check.GridN5AreaFirstVoltageCollapse 0.006.4413.250.872.950.190.342.1020.22
TransiEnt.Components.Electrical.PowerTransformation.Check.TestTransformerPiModelComplex (sim) 0.095.1813.202.040.140.030.082.8919.00
TransiEnt.Components.Gas.Combustion.Check.TestBurner_L1 (sim) 0.338.4413.130.712.300.100.185.1622.45
TransiEnt.Components.Gas.Combustion.Check.TestControllerBurner (sim) 0.4611.7213.350.773.170.160.297.3326.07
TransiEnt.Components.Gas.Compressor.Check.TestCompressors (sim) 0.669.1113.600.672.140.120.225.9723.91
TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor (sim) 1.1824.5113.592.853.631.270.5816.1739.82
TransiEnt.Components.Gas.Engines.Check.Test_Engine_idealGas 0.007.8813.480.712.540.100.224.3121.89
TransiEnt.Components.Gas.GasCleaning.Check.TestDryer_L1 0.000.5613.530.560.000.000.000.0014.72
TransiEnt.Components.Gas.GasCleaning.Check.TestPressureSwingAdsorptionReactor_L1 (sim) 0.386.6012.520.670.211.670.143.9120.00
TransiEnt.Components.Gas.HeatExchanger.Check.TestHeatExchanger (sim) 0.629.9412.500.802.170.130.246.6123.60
TransiEnt.Components.Gas.Reactor.Check.TestControllerH2AndH2OForReformer (sim) 0.1814.4712.550.753.040.201.199.3027.77
TransiEnt.Components.Gas.Reactor.Check.TestMethanator_L4_T_var 0.0012.1612.990.723.320.191.146.7825.71
TransiEnt.Components.Gas.Reactor.Check.TestMethanator_L4_m_flow_var 0.0011.9912.740.713.210.191.206.6925.29
TransiEnt.Components.Gas.Reactor.Check.TestPrereformer_L1 (sim) 0.298.5212.650.592.050.060.145.6821.98
TransiEnt.Components.Gas.Reactor.Check.TestSteamMethaneReformer_L4 (sim) 0.7611.5712.910.702.780.170.287.6425.80
TransiEnt.Components.Gas.Reactor.Check.TestWaterGasShiftReactor_L1 (sim) 0.187.1713.110.632.060.070.164.2521.00
TransiEnt.Components.Gas.VolumesValvesFittings.Base.PhysicalPL_L4 0.000.5412.710.540.000.000.000.0013.93
TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes (sim) 4.5433.3212.813.125.950.521.8321.9051.23
TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckRealGasJunction_L2 0.008.4712.840.823.731.170.402.3521.87
TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckRealGasJunction_L2_Quasistationary 0.000.7913.150.790.000.000.000.0014.63
TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckThreeWayValve (sim) 0.126.0512.860.620.150.041.783.4619.56
TransiEnt.Components.Gas.VolumesValvesFittings.Check.TestPhysicalPL_L4_wDist 0.000.7813.230.780.000.000.000.0014.71
TransiEnt.Components.Gas.VolumesValvesFittings.Check.TestPressureLosses (sim) 0.7217.0113.162.672.790.280.3910.8831.45
TransiEnt.Components.Gas.VolumesValvesFittings.Check.Test_Mixing_H2NG (sim) 0.8810.7913.060.752.720.140.266.9225.25
TransiEnt.Components.Heat.Check.TestHEX_ideal (sim) 0.093.2712.490.500.070.020.062.6216.33
TransiEnt.Components.Heat.Check.TestPipeGasAdvanced (sim) 0.1010.4112.350.622.880.170.256.4923.36
TransiEnt.Components.Heat.Check.TestSteamGenerator (sim) 0.022.2412.570.470.010.000.021.7315.34
TransiEnt.Components.Heat.Check.TestSteamTurbine (sim) 0.022.2112.250.420.010.000.021.7615.00
TransiEnt.Components.Heat.Check.TestSteamVolumeWithValve (sim) 0.022.5112.170.520.010.000.021.9615.25
TransiEnt.Components.Heat.Check.TestTurbineValveController (sim) 0.022.6012.460.480.010.010.032.0815.63
TransiEnt.Components.Heat.ElectricAirHeater.Check.TestElectricAirHeater (sim) 0.1010.3012.560.642.730.160.246.5223.52
TransiEnt.Components.Heat.Fan.Check.TestFan (sim) 0.195.7312.530.570.231.520.123.2919.02
TransiEnt.Components.Heat.Grid.Check.Test_ExpansionVessel (sim) 0.226.0113.000.630.201.570.133.4819.76
TransiEnt.Components.Heat.HeatRecoverySteamGenerator.Check.TestHeatRecoverySteamGenerator (sim) 0.1212.2412.470.652.750.181.067.5925.39
TransiEnt.Components.Heat.ThermalInsulation.Check.TestThermalInsulation (sim) 0.348.8112.280.632.280.110.195.6021.95
TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.Check.TestDoublePipePair_L2 0.000.5512.740.550.000.000.000.0014.00
TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.Check.TestSinglePipe_L2 0.000.5212.560.520.000.000.000.0013.73
TransiEnt.Components.Mechanical.Check.CheckInertiaConstant (sim) 0.137.0612.780.582.250.070.144.0120.50
TransiEnt.Components.Mechanical.Check.CheckTwoStateInertiaWithClutch (sim) 0.093.1812.510.580.090.020.072.4116.30
TransiEnt.Components.Sensors.Check.TestFrequencyStandardDeviation (sim) 7.632.8412.790.520.040.020.052.2123.84
TransiEnt.Components.Sensors.IdealGas.Check.TestIdealGasSensors 0.003.6712.480.600.140.031.641.2516.68
TransiEnt.Components.Sensors.RealGas.Check.TestRealGasSensors (sim) 0.199.9212.700.722.150.130.276.6623.34
TransiEnt.Components.Statistics.Check.TestBalancingPowerStatistics (sim) 0.116.0012.620.551.830.050.133.4419.28
TransiEnt.Components.Statistics.Check.TestPowerPlantStatistics (sim) 0.095.4812.950.560.150.041.772.9619.10
TransiEnt.Components.Statistics.Collectors.LocalCollectors.Check.CheckCollectElectricPower (sim) 0.083.1212.720.580.070.020.062.3916.47
TransiEnt.Components.Statistics.Collectors.LocalCollectors.Check.CheckHeatingPlantCost (sim) 0.083.0713.000.530.080.020.072.3716.69
TransiEnt.Components.Statistics.Collectors.LocalCollectors.Check.CheckPowerPlantCost (sim) 0.083.2613.110.550.080.020.062.5417.02
TransiEnt.Components.Statistics.Collectors.LocalCollectors.Check.CheckStorageCost (sim) 0.083.0812.730.520.080.020.072.3916.44
TransiEnt.Components.Statistics.PowerMarketModeling.MeritOrderModeling.Check.TestMeritOrderModel_f_RE_Conventionals_Demand (sim) 0.126.2712.750.662.010.060.133.4119.66
TransiEnt.Components.Turbogroups.Check.CheckTwoStateInertiaWitchClutch (sim) 0.093.0912.460.560.080.020.062.3716.16
TransiEnt.Components.Turbogroups.Check.TestGasTurbine (sim) 0.114.8912.601.920.100.030.072.7718.14
TransiEnt.Components.Turbogroups.Check.TestHydroTurbine (sim) 0.103.5912.290.610.110.030.082.7616.48
TransiEnt.Components.Turbogroups.Check.TestSlewRateLimited2StateTurbine (sim) 0.125.6712.910.600.171.700.113.0819.25
TransiEnt.Components.Turbogroups.Check.TestSlewRateLimitedTurbineStep (sim) 0.103.4512.820.560.100.020.072.6916.90
TransiEnt.Components.Turbogroups.OperatingStates.Check.TestPumpstorageStates (sim) 0.115.3012.550.520.130.031.503.1218.49
TransiEnt.Components.Turbogroups.OperatingStates.Check.TestThreeStateDynamic (sim) 0.103.3912.750.570.100.030.072.6316.78
TransiEnt.Components.Turbogroups.OperatingStates.Check.TestThreeStateDynamic_Initatmin (sim) 0.103.2812.510.480.090.020.072.6216.37
TransiEnt.Components.Visualization.Check.TestPowerSystemBasics (sim) 0.242.9412.960.530.040.020.052.3016.66
TransiEnt.Components.Visualization.Check.TestStatisticsVisualizationTable 0.000.6212.740.620.000.000.000.0014.03
TransiEnt.Components.Visualization.Check.Test_PQDiagram_Display 0.000.7612.960.690.070.000.000.0014.39
TransiEnt.Consumer.Electrical.Base.Check.CheckExponentialStatic (sim) 0.083.0713.400.590.080.020.062.3117.50
TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer (sim) 0.083.0513.070.620.080.020.062.2716.82
TransiEnt.Consumer.Electrical.Check.CheckDynamicExponentialElectricConsumerComplex (sim) 0.093.3313.340.600.090.020.062.5617.36
TransiEnt.Consumer.Electrical.Check.CheckExponentialElectricConsumer (sim) 0.093.2013.310.600.080.020.062.4417.46
TransiEnt.Consumer.Electrical.Check.CheckExponentialElectricConsumer2 (sim) 0.083.1613.310.580.080.020.062.4217.20
TransiEnt.Consumer.Electrical.Check.CheckLinearElectricConsumer (sim) 0.083.0413.040.610.080.020.062.2716.71
TransiEnt.Consumer.Electrical.Check.CheckLinearElectricConsumerSimpler (sim) 0.083.0312.990.610.080.020.062.2616.72
TransiEnt.Consumer.Electrical.Check.CheckSLPElectricConsumer (sim) 0.093.1212.900.570.070.020.072.3916.68
TransiEnt.Consumer.Electrical.Check.CheckTableBasedElectricConsumer (sim) 0.093.1513.030.570.070.020.072.4216.82
TransiEnt.Consumer.Gas.Check.GasDemandVarH2_varGCV_controlMFlow 0.003.7313.450.742.640.130.220.0017.93
TransiEnt.Consumer.Gas.Check.TestTableBasedGasBurningConsumer (sim) 4.267.0813.520.672.180.070.124.0325.43
TransiEnt.Consumer.Gas.Check.Test_GasDemandProfiler (sim) 0.086.0713.590.610.170.041.853.3920.33
TransiEnt.Consumer.Heat.Check.TestDomesticHotWater (sim) 0.093.1512.750.570.070.030.072.4116.56
TransiEnt.Consumer.Heat.Check.TestFirstOrderHeatingNetworkConsumer 0.000.6513.070.610.040.000.000.0014.37
TransiEnt.Consumer.Heat.Check.TestFirstOrderHeatingNetworkConsumer_withPlant 0.002.6612.572.500.160.000.000.0015.91
TransiEnt.Consumer.Heat.Check.TestIdealHeatingNetworkConsumer (sim) 0.125.6412.930.600.151.580.103.2219.31
TransiEnt.Consumer.Heat.Check.TestThermalHeatConsumer (sim) 0.107.6412.780.672.300.070.154.4521.14
TransiEnt.Consumer.Heat.Check.TestThermalHeatConsumer_L3 0.000.5712.760.570.000.000.000.0014.02
TransiEnt.Consumer.Heat.Profiles.ExampleHousehold_HotWaterDemand_VDI4665_60s (sim) 1.302.8813.060.570.040.010.052.2117.85
TransiEnt.Consumer.Heat.SpaceHeating.Check.CheckRoomTimeConstant (sim) 0.234.7212.971.850.100.030.072.6718.57
TransiEnt.Consumer.Heat.SpaceHeating.Check.ComputeDesignHeatLoad_EN12831 (sim) 3.295.4713.120.630.160.051.533.0922.48
TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating (sim) 2.775.5413.270.580.150.031.623.1622.77
TransiEnt.Consumer.Systems.FridgePoolControl.Check.TestPoolResponsePrequalification 0.000.5313.310.530.000.000.000.0014.52
TransiEnt.Consumer.Systems.FridgePoolControl.Components.SmartFridgeFreezer 0.000.5513.440.550.000.000.000.0014.69
TransiEnt.Consumer.Systems.FridgePoolControl.Pool.mainExplicitFridgePool 0.000.6113.450.610.000.000.000.0014.70
TransiEnt.Consumer.Systems.HeatpumpSystems.simulatePoolLoadShedding 0.000.6013.300.600.000.000.000.0014.57
TransiEnt.Consumer.Systems.HeatpumpSystems.simulateUnit 0.000.5613.400.560.000.000.000.0014.65
TransiEnt.Consumer.Systems.HouseholdEnergyConverter.Check.TestEnergyConverter_All 0.000.7113.790.710.000.000.000.0015.52
TransiEnt.Consumer.Systems.HouseholdEnergyConverter.Check.TestEnergyConverter_Single (sim) 0.127.3813.670.731.900.060.174.5221.75
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Base.Check.CheckLimitConditioning (sim) 0.012.6012.780.560.010.000.022.0116.17
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Base.Check.CheckPoolControlBus 0.000.4713.480.470.000.000.000.0014.58
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Base.Check.CheckPoolControlBusSumUp 0.000.4413.120.440.000.000.000.0014.18
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Base.Check.CheckPoolStoragePBPPotential (sim) 0.022.7312.860.560.030.010.032.1016.24
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Check.CheckExampleProfiles (sim) 0.433.0113.590.620.060.020.062.2717.69
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Check.CheckPVBatteryPool 0.002.7513.242.750.000.000.000.0016.71
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Check.CheckPVBatteryPoolSingleHouse 0.000.6913.710.690.000.000.000.0015.00
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Controller.Check.CheckBatteryConditioningController (sim) 0.022.5013.510.490.010.000.021.9716.63
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Controller.Check.CheckBatteryManagementSystem 0.000.5513.310.550.000.000.000.0014.59
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Controller.Check.CheckBatteryPrimaryBalancingController (sim) 0.133.0613.470.560.070.020.062.3417.37
TransiEnt.Consumer.Systems.PVBatteryPoolControl.Controller.Check.CheckPBPDispatcher (sim) 0.062.5613.420.540.010.010.031.9716.82
TransiEnt.Consumer.Systems.PVBatteryPoolControl.PVBatteryConsumer.Check.CheckPVBatteryHousehold 0.000.7013.380.700.000.000.000.0014.78
TransiEnt.Consumer.Systems.PVBatteryPoolControl.PVBatteryConsumer.Check.TestPoolControlledBatterySystem 0.000.6412.660.640.000.000.000.0014.20
TransiEnt.Examples.Coupled.Coupled_ElectricGrid 0.003.0913.932.940.160.000.000.0017.65
TransiEnt.Examples.Coupled.Coupled_ElectricGrid_DHN 0.000.7613.640.760.000.000.000.0015.06
TransiEnt.Examples.Coupled.Coupled_ElectricGrid_DHN_GasGrid 0.002.6213.472.620.000.000.000.0016.77
TransiEnt.Examples.Coupled.Coupled_ElectricGrid_GasGrid 0.006.1313.473.642.500.000.000.0020.28
TransiEnt.Examples.Coupled.Coupled_LargeScale 0.000.6413.290.640.000.000.000.0014.56
TransiEnt.Examples.Coupled.Coupled_SmallScale 0.002.7713.262.770.000.000.000.0016.66
TransiEnt.Examples.Electric.ElectricGrid_SecondaryBalancing (sim) 0.167.9914.070.692.470.100.164.5722.74
TransiEnt.Examples.Electric.ElectricGrid_StandAlone 0.002.3213.910.781.530.000.000.0016.86
TransiEnt.Examples.Gas.GasGrid_StandAlone 0.0037.3013.623.7618.732.052.3010.4551.42
TransiEnt.Examples.Gas.Test_GasGrid_SubSystem 0.0037.4813.683.7919.252.022.3910.0351.70
TransiEnt.Examples.GridTypology_Cologne.BlockDevelopment.GridTypology_2015 0.0010.7013.2510.700.000.000.000.0024.70
TransiEnt.Examples.GridTypology_Cologne.BlockDevelopment.GridTypology_2050 0.0010.5313.2110.530.000.000.000.0024.44
TransiEnt.Examples.GridTypology_Cologne.BlockDevelopment_DHN.GridTypology_DHN_2015 0.0010.6113.5410.610.000.000.000.0024.89
TransiEnt.Examples.GridTypology_Cologne.BlockDevelopment_DHN.GridTypology_DHN_2050 0.0010.5713.4810.570.000.000.000.0024.76
TransiEnt.Examples.Hamburg.ElectricGrid 0.002.3413.482.340.000.000.000.0016.47
TransiEnt.Examples.Hamburg.GasGrid_PtG 0.000.4712.920.470.000.000.000.0014.01
TransiEnt.Examples.Hamburg.SectorCouplingPtH 0.003.1713.063.170.000.000.000.0016.90
TransiEnt.Examples.Hamburg.SectorCouplingPtX 0.002.9213.152.920.000.000.000.0016.74
TransiEnt.Examples.Heat.DHN_StandAlone 0.000.7113.500.710.000.000.000.0014.83
TransiEnt.Examples.Heat.ElectricThermalEnergyStorage 0.000.6713.570.670.000.000.000.0014.88
TransiEnt.Examples.Heat.Test_DHN_SubSystem 0.000.7113.780.710.000.000.000.0015.12
TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestDiscretizePrediction (sim) 0.093.0213.040.570.040.010.052.3516.74
TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestLoadPredictionAdaption (sim) 0.103.1212.740.590.060.020.062.4016.60
TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestMeritOrderDispatcher 0.007.7012.520.536.940.100.120.0020.93
TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestMeritOrderDispatcherStatePrediction 0.002.5112.880.590.130.031.750.0016.35
TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestMeritOrderDispatcher_noPred 0.000.7712.850.590.090.020.070.0014.31
TransiEnt.Grid.Electrical.LumpedPowerGrid.Check.LocalPlantInteractingWithUCTE (sim) 0.097.2913.620.742.390.070.153.9421.60
TransiEnt.Grid.Electrical.LumpedPowerGrid.Check.LocalPlantInteractingWithUCTE_withIncident (sim) 0.126.9213.470.612.320.060.143.7821.17
TransiEnt.Grid.Electrical.LumpedPowerGrid.Check.TestLumpedGrid_PrimaryResponse (sim) 0.095.9913.470.632.120.050.123.0720.17
TransiEnt.Grid.Electrical.LumpedPowerGrid.Check.TestTwoGridArchitecture (sim) 0.096.6013.200.632.250.060.133.5320.94
TransiEnt.Grid.Electrical.LumpedPowerGrid.Check.TestTwoSubgridStatistics (sim) 0.148.5613.120.782.530.120.234.9022.45
TransiEnt.Grid.Electrical.Noise.Base.GenerateRealisticGridError_1year_60s (sim) 48.903.2013.600.640.100.020.062.3966.31
TransiEnt.Grid.Electrical.Noise.Check.TestTwoGridsWithErrors (sim) 0.266.1113.620.651.910.060.123.3720.62
TransiEnt.Grid.Electrical.Noise.Check.TestUCTE_typicalGridErrors (sim) 0.615.5013.280.561.740.050.123.0320.03
TransiEnt.Grid.Electrical.SecondaryControl.Check.TestScheduleActivation (sim) 0.072.9012.760.570.060.020.052.2016.27
TransiEnt.Grid.Electrical.SecondaryControl.Check.TestSecondaryBalancingController (sim) 0.092.9613.160.460.070.020.052.3516.78
TransiEnt.Grid.Electrical.UnitCommitment.Check.TestBinarySchedule (sim) 0.175.0913.510.510.140.041.602.7919.44
TransiEnt.Grid.Electrical.UnitCommitment.Check.TestBinarySchedule_fwd (sim) 0.9517.1813.362.341.601.300.4411.4932.03
TransiEnt.Grid.Electrical.UnitCommitment.Check.TestSimplifiedUnitCommitment 0.005.5613.090.534.690.150.180.0019.41
TransiEnt.Grid.Gas.Check.TestGasGridHamburg 0.000.5512.920.550.000.000.000.0014.12
TransiEnt.Grid.Gas.Check.TestGasGridHamburgVarGCV 0.000.5212.830.520.000.000.000.0013.95
TransiEnt.Grid.Gas.Check.TestGasGridHamburgVarGCVPtG 0.000.5112.950.510.000.000.000.0014.13
TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks (sim) 13.0953.5512.592.7916.630.783.0030.3582.29
TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCycMix (sim) 27.6033.9412.603.108.130.571.6720.4777.76
TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCycMix2 (sim) 25.9736.6012.642.989.121.371.4121.7177.57
TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCycSourcePipeSink (sim) 4.208.0912.590.712.330.100.174.7828.12
TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCycSplit (sim) 9.7821.9012.932.735.360.331.8311.6448.33
TransiEnt.Grid.Heat.HeatGridAnalysis.ClosedLoop_PressureControlled (sim) 0.1619.4812.932.763.810.281.3711.2634.97
TransiEnt.Grid.Heat.HeatGridAnalysis.OpenLoop_MassFlow_and_Pressure_Controlled (sim) 0.1619.4912.892.753.920.260.9911.5735.29
TransiEnt.Grid.Heat.HeatGridAnalysis.TwoClosedLoops_PressureControlled (sim) 0.2633.2212.903.077.920.412.2719.5546.93
TransiEnt.Grid.Heat.HeatGridControl.Check.TestDemandInDifferentCities (sim) 0.093.6711.880.390.080.030.302.8617.67
TransiEnt.Grid.Heat.HeatGridControl.Check.TestHeatFlowDivision (sim) 0.012.0711.940.380.010.010.031.6415.22
TransiEnt.Grid.Heat.HeatGridControl.Check.TestMassFlowCharacteristicLines (sim) 0.022.3811.750.380.020.010.271.7116.62
TransiEnt.Grid.Heat.HeatGridControl.Check.TestSupplyAndReturnTemperatureDHG (sim) 0.022.1411.070.410.010.010.031.6813.84
TransiEnt.Grid.Heat.HeatGridControl.Check.TestWeeklyHeatProfile (sim) 0.072.9312.300.440.060.020.062.3517.19
TransiEnt.Grid.Heat.HeatGridControl.Check.Test_DHG_FeedForward_Controller (sim) 0.094.9510.830.450.160.051.432.8716.70
TransiEnt.Grid.Heat.HeatGridControl.Check.Test_HeatDemandPrediction (sim) 0.327.3912.910.530.150.042.114.5726.24
TransiEnt.Grid.Heat.HeatGridControl.Controllers.DHG_FeedForward_Controller (sim) 0.062.8311.150.450.050.020.052.2714.64
TransiEnt.Grid.Heat.HeatGridTopology.Check.Test_DHG_Topology_HH_1port_3sites_SimpleGrid 0.003.2411.272.980.270.000.000.0015.17
TransiEnt.Grid.Heat.HeatGridTopology.Check.Test_DHG_Topology_HH_2ports_2sites_ClosedGrid 0.003.2411.272.950.290.000.000.0015.21
TransiEnt.Producer.Combined.LargeScaleCHP.Base.Check.TestCHPStates_electricityled (sim) 0.095.2513.390.570.110.031.652.8819.27
TransiEnt.Producer.Combined.LargeScaleCHP.Base.Check.TestHeatInputTable (sim) 0.032.6413.820.560.020.010.032.0217.01
TransiEnt.Producer.Combined.LargeScaleCHP.Base.Check.TestPQBoundaries (sim) 0.022.5313.420.500.010.010.021.9916.50
TransiEnt.Producer.Combined.LargeScaleCHP.Check.TestCHP_balancingControlOffer 0.000.6413.650.640.000.000.000.0014.99
TransiEnt.Producer.Combined.LargeScaleCHP.Check.TestCHP_startup 0.000.7013.300.700.000.000.000.0014.70
TransiEnt.Producer.Combined.LargeScaleCHP.Check.TestContinuousCHP_startup 0.002.6413.420.831.810.000.000.0016.71
TransiEnt.Producer.Combined.LargeScaleCHP.Check.TestDetailedCHP 0.000.6513.460.650.000.000.000.0014.81
TransiEnt.Producer.Combined.LargeScaleCHP.Check.TestH2CofiringCHP 0.000.7713.270.710.060.000.000.0014.70
TransiEnt.Producer.Combined.LargeScaleCHP.Check.TestTwoBlockCHP 0.003.0513.282.930.120.000.000.0017.03
TransiEnt.Producer.Combined.SmallScaleCHP.Check.TestSmallScaleCHP_L1_idContrMFlow_temp (sim) 0.106.6513.420.752.110.160.133.5020.81
TransiEnt.Producer.Combined.SmallScaleCHP.Check.Test_CHP_ice 0.000.7213.420.720.000.000.000.0014.84
TransiEnt.Producer.Combined.SmallScaleCHP.SmallScaleCHP_simple.Check.TestSmallScaleCHP_simple (sim) 0.128.0013.420.852.360.070.184.5422.48
TransiEnt.Producer.Combined.SmallScaleCHP.SmallScaleCHP_simple.Check.TestSmallScaleCHP_simple_with_control (sim) 0.107.5213.380.782.310.070.174.2021.51
TransiEnt.Producer.Combined.SmallScaleCHP.SmallScaleCHP_simple.Check.TestSmallScaleCHPsystem (sim) 0.127.4013.300.802.240.060.164.1321.43
TransiEnt.Producer.Electrical.Controllers.Check.TestPrimaryBalancingController (sim) 0.093.4113.260.570.110.030.082.6217.29
TransiEnt.Producer.Electrical.Controllers.Check.TestSimpleTwoBlockCoordination (sim) 0.093.3512.850.590.080.030.072.5916.88
TransiEnt.Producer.Electrical.Conventional.Check.CheckBlackCoal (sim) 0.116.1213.340.621.900.060.123.4220.10
TransiEnt.Producer.Electrical.Conventional.Check.CheckBlackCoal_Init (sim) 0.106.3313.410.632.060.050.123.4720.42
TransiEnt.Producer.Electrical.Conventional.Check.CheckBlackCoal_PriBal (sim) 0.118.4413.120.712.320.100.215.1022.23
TransiEnt.Producer.Electrical.Conventional.Check.CheckBlackCoal_Schedule (sim) 0.096.0113.310.661.820.050.113.3719.97
TransiEnt.Producer.Electrical.Conventional.Check.CheckBlackCoal_twoVariants (sim) 0.137.0513.090.582.070.070.134.2020.83
TransiEnt.Producer.Electrical.Conventional.Check.CheckCCP (sim) 0.128.4613.300.682.390.130.205.0722.42
TransiEnt.Producer.Electrical.Conventional.Check.CheckCCP_with_GasPort_CCS (sim) 2.2211.0213.172.701.080.190.326.7326.95
TransiEnt.Producer.Electrical.Conventional.Check.CheckCCP_with_GasPort_MinimumDownTime (sim) 2.149.8813.252.560.870.170.276.0125.85
TransiEnt.Producer.Electrical.Conventional.Check.CheckCCP_with_SecondGasPort 0.003.1113.110.812.300.000.000.0016.93
TransiEnt.Producer.Electrical.Conventional.Check.CheckGasturbine (sim) 0.116.2413.170.651.960.060.133.4320.10
TransiEnt.Producer.Electrical.Conventional.Check.CheckGasturbine_SecondaryControl (sim) 0.116.1913.470.572.040.060.133.3920.32
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckFourthOrderPlant (sim) 0.103.8413.130.550.130.030.083.0417.62
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckNonlinearThreeStatePlant_Loadramp (sim) 0.146.9813.120.632.100.070.134.0520.79
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckNonlinearThreeStatePlant_Loadstep (sim) 0.137.2513.320.712.210.080.144.1121.27
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckNonlinearThreeStatePlant_PrimaryControl 0.000.6713.380.630.040.000.000.0014.68
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckNonlinearThreeStatePlant_SecondaryControl (sim) 0.126.3213.490.602.090.050.123.4520.50
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckSecondOrderPlant_Startup (sim) 0.105.3913.110.580.140.031.752.8919.16
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckSecondOrderPlant_VDIVDE3507 (sim) 0.085.4113.500.580.150.031.653.0019.57
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckSimplePowerPlant (sim) 0.105.0913.330.560.141.390.092.9119.08
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckVDI3508 (sim) 0.095.9512.970.600.211.650.123.3619.60
TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckVDI3508PBPlant (sim) 0.126.0812.990.611.860.050.123.4319.73
TransiEnt.Producer.Electrical.Conventional.Components.Check.TestDetailedSteamPowerPlant (sim) 0.42107.2213.135.7459.171.423.0437.85121.33
TransiEnt.Producer.Electrical.Conventional.Components.Check.TestReplaceablePowerPlantModels (sim) 0.115.9113.260.610.211.720.123.2519.82
TransiEnt.Producer.Electrical.Others.Check.TestBiomass (sim) 0.096.1013.220.562.060.050.133.3019.95
TransiEnt.Producer.Electrical.Others.Check.TestIdealContinuousBiomassPlant (sim) 0.083.4013.220.550.090.020.072.6617.28
TransiEnt.Producer.Electrical.Others.Check.TestIdealContinuousHydropowerPlant (sim) 0.083.2813.300.540.090.020.082.5517.22
TransiEnt.Producer.Electrical.Others.Check.TestPumpedStoragePlant (sim) 0.107.0513.240.692.200.090.143.9320.92
TransiEnt.Producer.Electrical.Others.Check.TestPumpedStoragePlant_Gradients (sim) 0.106.0313.400.562.060.050.123.2320.09
TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.Check.Test_Advanced_PV_WeatherHamburg (sim) 1.518.1213.230.702.470.110.244.6123.45
TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.DNIDHI_Input.Check.Check_PVModule (sim) 0.143.9313.370.630.130.030.093.0617.96
TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.DNIDHI_Input.Check.Check_PVModule_inputPOAirradiation (sim) 0.113.6913.490.560.100.030.072.9317.83
TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.DNIDHI_Input.Check.Check_PVPlant (sim) 0.135.7013.220.640.170.041.843.0219.62
TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.GHI_Input.Check.Check_PVModule (sim) 0.253.6913.380.580.120.030.082.8817.86
TransiEnt.Producer.Electrical.Photovoltaics.Advanced_PV.GHI_Input.Check.Check_PVPlant (sim) 0.245.3913.700.560.160.041.712.9219.88
TransiEnt.Producer.Electrical.Photovoltaics.Check.Check_DataSheetBasedPV (sim) 0.083.3512.640.530.100.030.072.6216.61
TransiEnt.Producer.Electrical.Photovoltaics.Check.Check_OneDiodeModel (sim) 0.093.2412.910.580.080.020.072.4816.80
TransiEnt.Producer.Electrical.Photovoltaics.Check.Check_PhotovoltaicPlant (sim) 0.143.3913.930.590.100.030.122.5517.98
TransiEnt.Producer.Electrical.Photovoltaics.Check.Check_PhotovoltaicProfilePlant (sim) 0.083.2813.030.540.090.020.062.5716.95
TransiEnt.Producer.Electrical.Photovoltaics.PVProfiles.Check.Check_SolarProfileLoader (sim) 0.162.8313.250.560.040.020.052.1616.79
TransiEnt.Producer.Electrical.Photovoltaics.QuasiStationary.Check.TestConstantEfficiencyPVModule (sim) 0.113.4413.670.550.130.030.082.6617.75
TransiEnt.Producer.Electrical.Photovoltaics.QuasiStationary.Check.TestLowVoltageGridWithPVModules (sim) 0.487.4613.330.762.150.050.144.3721.83
TransiEnt.Producer.Electrical.Photovoltaics.QuasiStationary.Check.TestPhotovoltaicPlantQS (sim) 0.093.0613.860.580.080.020.062.3217.59
TransiEnt.Producer.Electrical.Wind.Base.Check.TestDrydenTurbulence (sim) 0.173.1012.910.540.060.020.062.4316.71
TransiEnt.Producer.Electrical.Wind.Base.Check.TestWindturbineRotor (sim) 0.083.0013.010.510.070.020.062.3316.60
TransiEnt.Producer.Electrical.Wind.Base.Check.Test_RoughnessFilter (sim) 0.082.9812.950.490.050.020.062.3716.53
TransiEnt.Producer.Electrical.Wind.Check.TestIdealWindpark (sim) 0.115.8812.840.631.880.050.103.2219.36
TransiEnt.Producer.Electrical.Wind.Check.TestPowerCurveWindPlant (sim) 0.095.3712.690.580.140.031.632.9818.68
TransiEnt.Producer.Electrical.Wind.Check.TestPowerCurveWindPlant_scaling (sim) 0.083.4812.900.550.130.030.082.6816.96
TransiEnt.Producer.Electrical.Wind.Check.TestPowerProfileWindPlant (sim) 0.083.2412.780.520.080.020.072.5516.66
TransiEnt.Producer.Electrical.Wind.Check.TestWindpark 0.002.7212.720.540.151.470.110.4715.95
TransiEnt.Producer.Electrical.Wind.Check.TestWindturbine (sim) 0.115.7312.690.581.960.050.133.0119.09
TransiEnt.Producer.Electrical.Wind.Check.TestWindturbine2 (sim) 0.105.9012.490.531.880.060.123.3118.99
TransiEnt.Producer.Electrical.Wind.Check.TestWindturbine_SI_DF (sim) 0.106.2212.410.602.110.070.133.3119.25
TransiEnt.Producer.Electrical.Wind.Check.TestWindturbine_turbulence (sim) 0.865.9412.510.651.880.050.113.2419.84
TransiEnt.Producer.Electrical.Wind.Check.Test_WTG_SI_df_dt (sim) 0.135.8712.610.561.930.070.123.1919.17
TransiEnt.Producer.Electrical.Wind.Controller.Check.TestPitchController (sim) 0.124.9512.910.590.150.031.562.6218.50
TransiEnt.Producer.Electrical.Wind.Controller.TorqueController 0.000.5412.870.540.000.000.000.0014.04
TransiEnt.Producer.Electrical.Wind.Controller.TorqueController_SI_deltaF 0.000.5312.910.530.000.000.000.0014.14
TransiEnt.Producer.Electrical.Wind.Controller.TorqueController_SI_df_dt 0.000.5212.650.520.000.000.000.0013.82
TransiEnt.Producer.Gas.BiogasPlant.Base.ADM1.ADM1_CSTR 0.000.5513.280.550.000.000.000.0014.48
TransiEnt.Producer.Gas.BiogasPlant.Check.Check_StirredTankReactor 0.000.5913.300.590.000.000.000.0014.53
TransiEnt.Producer.Gas.BiogasPlant.Check.TestADM1 0.000.5413.660.540.000.000.000.0014.97
TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer (sim) 0.1711.2912.962.961.030.190.296.8224.94
TransiEnt.Producer.Gas.Electrolyzer.Check.TestPEMElectrolyzer_L1_Charline 0.004.5013.040.682.140.060.171.4618.05
TransiEnt.Producer.Gas.Electrolyzer.Check.TestPEMElectrolyzer_L1_Charline_HeatProvision (sim) 0.7211.7712.812.871.080.210.327.3025.84
TransiEnt.Producer.Gas.Electrolyzer.Check.TestPEMElectrolyzer_L1_Dynamics (sim) 0.307.0812.730.702.080.070.144.1020.63
TransiEnt.Producer.Gas.Electrolyzer.Check.Test_400A_Espinosa_L2 (sim) 0.156.2812.890.702.150.050.123.2619.83
TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.TestElectrolyzerAndCavern 0.000.7413.320.680.060.000.000.0014.68
TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.Test_FeedInStation_CavernComp 0.004.7113.410.802.320.130.261.2018.65
TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.Test_FeedInStation_HeatProvision 0.006.8413.632.531.280.221.331.4921.00
TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.Test_FeedInStation_Storage 0.004.6613.050.842.420.110.211.0918.22
TransiEnt.Producer.Gas.Electrolyzer.Systems.Check.Test_FeedInStation_woStorage 0.004.0513.210.712.240.060.140.9117.77
TransiEnt.Producer.Gas.MethanatorSystem.Check.Test_FeedInStation_Methanator 0.005.5313.325.530.000.000.000.0019.59
TransiEnt.Producer.Gas.MethanatorSystem.Check.Test_FeedInStation_Methanator_WithCoolant 0.003.7313.143.730.000.000.000.0017.53
TransiEnt.Producer.Gas.MethanatorSystem.Check.Test_MethanatorSystem 0.002.0013.382.000.000.000.000.0016.00
TransiEnt.Producer.Gas.MethanatorSystem.EquilibriumModel.Check.Check_MethanatorBlock_equilibrium_L2 0.002.8513.332.850.000.000.000.0016.82
TransiEnt.Producer.Gas.MethanatorSystem.EquilibriumModel.Check.Check_MethanatorBlock_equilibrium_L2_ 0.003.9113.233.910.000.000.000.0017.84
TransiEnt.Producer.Gas.SteamMethaneReformerSystem.Check.TestSMRSystem_noH2Loop 0.000.7413.650.740.000.000.000.0015.04
TransiEnt.Producer.Gas.SteamMethaneReformerSystem.Check.TestSMRSystem_noH2Loop_wContr 0.000.7513.640.750.000.000.000.0015.06
TransiEnt.Producer.Heat.Gas2Heat.Check.HeatPumpGasCharlineTest (sim) 0.339.4213.212.630.690.130.235.7423.47
TransiEnt.Producer.Heat.Gas2Heat.Check.Test_idContrMFlow_temp (sim) 0.127.6512.800.722.170.060.164.5521.13
TransiEnt.Producer.Heat.Gas2Heat.SimpleGasBoiler.Check.TestGasBoilerGasAdaptive_L1 0.003.5212.900.712.500.100.210.0017.08
TransiEnt.Producer.Heat.Gas2Heat.SimpleGasBoiler.Check.TestGasBoiler_L1 (sim) 0.2210.5513.042.870.940.180.286.2724.33
TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_L1 0.005.9113.000.672.000.080.133.0419.40
TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_L2 0.000.5412.960.540.000.000.000.0014.13
TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1 0.005.9612.790.682.040.060.123.0519.26
TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_Qflowset 0.006.2012.860.722.190.070.143.0819.56
TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_Qflowset_variableH2 0.003.1112.810.682.200.080.140.0016.55
TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_Qflowset_variableST 0.006.0413.130.712.150.070.132.9819.69
TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoilers_HoldTemperature_L2 0.000.5313.010.530.000.000.000.0014.13
TransiEnt.Producer.Heat.Heat2Heat.Check.TestSubstation_indirect_noStorage_L1 (sim) 0.095.5412.930.600.140.031.643.1319.06
TransiEnt.Producer.Heat.HeaterCooler.Check.TestSupplementaryHeater_L0 (sim) 0.166.4512.430.671.920.050.123.6919.57
TransiEnt.Producer.Heat.Power2Heat.Check.TestConverter_Heat2Power (sim) 0.072.7912.490.430.040.020.042.2615.86
TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestElectricBoiler_L1 (sim) 0.106.3212.960.712.170.050.133.2619.90
TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter (sim) 0.206.2712.470.672.050.050.123.3919.43
TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.Test_idContrMFlow_temp (sim) 0.116.9712.830.722.180.070.123.8720.44
TransiEnt.Producer.Heat.Power2Heat.Heatpump.Check.HeatPumpElectricCharlineTest (sim) 0.117.4112.670.752.270.070.144.1820.70
TransiEnt.Producer.Heat.Power2Heat.Heatpump.Check.TestHeatpump (sim) 0.115.9413.120.661.900.050.133.2119.70
TransiEnt.Producer.Heat.Power2Heat.Heatpump.Check.TestHeatpumpSystem (sim) 0.085.2612.890.661.790.040.092.6818.74
TransiEnt.Producer.Heat.Power2Heat.Heatpump.Check.TestHeatpumpWithControl_HeatingSystem (sim) 0.125.6712.760.601.790.040.113.1319.05
TransiEnt.Producer.Heat.Power2Heat.Heatpump.Check.TestHeatpumpWithControl_OnOff (sim) 0.155.7212.930.681.750.060.113.1119.34
TransiEnt.Producer.Heat.Power2Heat.Heatpump.Check.TestHeatpumpWithControl_bivalent_fluidports_ramp (sim) 0.156.2712.770.611.970.050.123.5219.69
TransiEnt.Producer.Heat.Power2Heat.Heatpump.Check.TestHeatpumpWithControl_bivalent_fluidports_sine (sim) 0.147.0513.080.681.980.060.154.1720.75
TransiEnt.Producer.Heat.SolarThermal.Base.SolarTime (sim) 0.022.2812.860.480.010.000.021.7815.69
TransiEnt.Producer.Heat.SolarThermal.Check.TestCollectorEN12975 (sim) 5.756.6312.690.661.820.060.143.9625.61
TransiEnt.Producer.Heat.SolarThermal.Check.TestCollectorFieldEN12975 (sim) 0.2217.0412.702.752.840.270.4710.7130.50
TransiEnt.Producer.Heat.SolarThermal.Check.TestCollectorFieldFluidCycle 0.000.5112.730.510.000.000.000.0013.90
TransiEnt.Producer.Heat.SolarThermal.Check.TestCollectorFluidCycle_constProp 0.000.5312.730.530.000.000.000.0013.90
TransiEnt.Producer.Heat.SolarThermal.Check.TestCollectorFluidCycle_constProp2 0.000.5212.710.520.000.000.000.0013.82
TransiEnt.Producer.Heat.SolarThermal.Check.TestCollector_noFluidPorts (sim) 0.425.3612.880.570.200.041.602.9619.18
TransiEnt.Producer.Heat.SolarThermal.Check.TestSolarThermal_L0 (sim) 0.083.5512.730.550.110.030.082.7816.88
TransiEnt.Producer.Heat.SolarThermal.SystemModels.Check.TestSolarThermalSystem 0.000.6912.930.690.000.000.000.0014.25
TransiEnt.Storage.Base.Check.TestGenericStorage (sim) 0.093.9311.261.520.090.030.072.2115.83
TransiEnt.Storage.Base.Check.TestGenericStorageHyst (sim) 0.114.4011.400.530.110.031.242.4917.05
TransiEnt.Storage.Base.Check.TestLinearStationaryLoss 0.000.5011.460.500.000.000.000.0012.54
TransiEnt.Storage.Electrical.Base.Check.TestBatteryEfficiency (sim) 0.023.0112.210.500.010.000.082.4317.96
TransiEnt.Storage.Electrical.Base.Check.TestGenericElectricStorage (sim) 0.105.6311.990.611.550.050.163.2620.07
TransiEnt.Storage.Electrical.Base.Check.TestGenericElectricStorageHyst (sim) 0.125.9512.090.621.530.061.032.7120.91
TransiEnt.Storage.Electrical.Check.TestCAES (sim) 0.104.7011.140.530.110.031.472.5716.48
TransiEnt.Storage.Electrical.Check.TestFlywheelDischarge 0.000.5412.120.490.040.000.000.0017.18
TransiEnt.Storage.Electrical.Check.TestFlywheelEfficiency 0.000.4712.050.430.040.000.000.0015.67
TransiEnt.Storage.Electrical.Check.TestFlywheelPark_L2_Efficiency 0.000.4911.780.400.090.000.000.0014.42
TransiEnt.Storage.Electrical.Check.TestIdealStorageLoadSmoothing 0.000.4112.110.410.000.000.000.0015.63
TransiEnt.Storage.Electrical.Check.TestLeadAcidBattery (sim) 0.165.2711.790.481.540.060.123.0717.76
TransiEnt.Storage.Electrical.Check.TestLithiumIonBattery (sim) 0.165.3211.620.481.550.060.133.1117.70
TransiEnt.Storage.Electrical.Check.TestPrimaryControlWithBattery (sim) 0.124.6812.030.411.330.040.102.8018.17
TransiEnt.Storage.Electrical.Check.TestPumpedStorage (sim) 0.165.3312.520.640.130.041.892.6318.49
TransiEnt.Storage.Electrical.Check.TestSuperCapacitor (sim) 0.105.3112.320.650.130.031.862.6418.23
TransiEnt.Storage.Electrical.Controller.Check.TestLoadSmoothingController (sim) 0.185.3012.420.630.130.031.892.6218.44
TransiEnt.Storage.Gas.Check.TestGasStorageVesselHeatTransfer_L2 (sim) 8.5810.1512.890.812.400.140.256.5432.15
TransiEnt.Storage.Gas.Check.TestGasStorage_L1 (sim) 0.146.7213.120.561.900.070.124.0820.49
TransiEnt.Storage.Gas.Check.TestGasStorage_constXi_L2 (sim) 5.959.4912.450.802.670.100.225.6928.43
TransiEnt.Storage.Gas.Check.TestGasStorage_varXi 0.000.8212.850.820.000.000.000.0014.31
TransiEnt.Storage.Gas.Check.TestUndergroundGasStorageHeatTransfer_L2 (sim) 0.377.5612.450.772.360.070.144.2220.93
TransiEnt.Storage.Gas.Check.TestUndergroundGasStorageIdealHTInPipes_L2 (sim) 0.537.5413.080.662.010.080.174.6121.64
TransiEnt.Storage.Gas.Check.TestUndergroundGasStoragePressureLoss_L2 (sim) 1.0010.8612.362.910.970.190.286.5124.69
TransiEnt.Storage.Heat.ElectricWaterHeater_constProp_L4.Check.CheckStratifiedElectricWaterHeater_CoolDown (sim) 0.075.9613.090.520.350.071.443.5819.63
TransiEnt.Storage.Heat.ElectricWaterHeater_constProp_L4.Check.CheckStratifiedElectricWaterHeater_Healy (sim) 0.033.3612.810.480.140.030.062.6516.72
TransiEnt.Storage.Heat.ElectricWaterHeater_constProp_L4.ElectricWaterHeater_constProp_L4 0.000.5812.150.500.090.000.000.0013.33
TransiEnt.Storage.Heat.HotWaterStorage_L2.Check.Check_HotWaterStorage_L2 (sim) 0.075.4113.160.560.130.031.613.0819.13
TransiEnt.Storage.Heat.HotWaterStorage_L4.Checks.TestStratifiedHotWaterStorage_L4 (sim) 0.146.6413.490.661.910.060.123.8920.78
TransiEnt.Storage.Heat.HotWaterStorage_L4.Checks.Test_FluidVolume_01 (sim) 0.115.2613.080.600.130.031.503.0018.93
TransiEnt.Storage.Heat.HotWaterStorage_L4.Checks.Test_FluidVolume_02 (sim) 0.115.2013.170.640.130.041.412.9718.96
TransiEnt.Storage.Heat.HotWaterStorage_L4.Checks.Test_HeatStorageL4_Electrical (sim) 0.2810.9313.180.802.730.210.326.8624.94
TransiEnt.Storage.Heat.HotWaterStorage_constProp_L2.Check.Check_HotWaterStorage_constProp_L2 (sim) 0.097.0513.100.632.040.050.134.2020.71
TransiEnt.Storage.Heat.HotWaterStorage_constProp_L4.Check.CheckStratifiedHotWaterStorage_L4_Loading 0.000.5912.250.590.000.000.000.0013.45
TransiEnt.Storage.Heat.HotWaterStorage_constProp_L4.Check.CheckStratifiedHotWaterStorage_L4_Loading_inclElHeater (sim) 0.3114.8312.232.921.911.430.388.1827.88
TransiEnt.Storage.Heat.HotWaterStorage_constProp_L4.Check.CheckStratifiedHotWaterStorage_L4_Standbyloss (sim) 0.2714.1012.382.711.500.341.448.1227.32
TransiEnt.Storage.Heat.HotWaterStorage_constProp_L4.Check.CheckStratifiedHotWaterStorage_L4_Unloading 0.000.5912.300.590.000.000.000.0013.52
TransiEnt.Storage.Heat.HotWaterStorage_constProp_L4.Check.CheckStratifiedHotWaterStorage_L4_noFluidPorts (sim) 0.105.2713.010.640.110.031.752.7318.89
TransiEnt.Storage.Heat.PackedBedStorage_L4.Check.TestPackedBedStorage 0.000.5213.290.520.000.000.000.0014.41
TransiEnt.SystemGeneration.GridConstructor.Check.TestGridConstructor 0.002.9813.422.980.000.000.000.0016.98
TransiEnt.SystemGeneration.GridConstructor.Check.TestGridConstructor_noGasGrid 0.002.7913.322.790.000.000.000.0016.72
TransiEnt.SystemGeneration.Superstructure.Components.LocalHeatSupply.LocalHeatingDemand_HeatStorage 0.000.5813.430.580.000.000.000.0014.65
TransiEnt.SystemGeneration.Superstructure.Scenarios.Example_Scenario 0.000.6113.150.610.000.000.000.0014.36