Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=1500 tolerance=1e-06 numberOfIntervals=150 stepSize=10 Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Others.Check.TestPumpedStoragePlant_Gradients -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | ##CVODE## -1 error occurred at time = 20.8695051627963 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 20.8695 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0289214s reading init.xml | | | | | | 0.00172754s reading info.xml | | | | | | 0.000290545s [ 0.6%] pre-initialization | | | | | | 0.043518s [ 96.5%] initialization | | | | | | 0.000994465s [ 2.2%] steps | | | | | | 0.000714186s [ 1.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.8706e-05s [ 0.0%] event-handling | | | | | | 9.667e-06s [ 0.0%] overhead | | | | | | -0.00043329s [ -1.0%] simulation | | | | | | 0.0451122s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 1041 steps taken | | | | | | 1193 calls of functionODE | | | | | | 24 evaluations of jacobian | | | | | | 8 error test failures | | | | | | 2 convergence test failures | | | | | | 0s time of jacobian evaluation