Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckVDI3508 -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | ##CVODE## -1 error occurred at time = 11115.5360835221 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 11115.5 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0201123s reading init.xml | | | | | | 0.00182903s reading info.xml | | | | | | 0.000300123s [ 0.6%] pre-initialization | | | | | | 0.0426774s [ 88.7%] initialization | | | | | | 0.000975559s [ 2.0%] steps | | | | | | 0.00152225s [ 3.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 4.4597e-05s [ 0.1%] event-handling | | | | | | 0.000703046s [ 1.5%] overhead | | | | | | 0.0018845s [ 3.9%] simulation | | | | | | 0.0481075s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 2091 steps taken | | | | | | 2366 calls of functionODE | | | | | | 61 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 14 convergence test failures | | | | | | 0s time of jacobian evaluation