| Total | Frontend | Backend | SimCode | Templates | Compilation | Simulation | Verification |
|---|---|---|---|---|---|---|---|
| 1865 | 1839 | 1838 | 1834 | 1834 | 1831 | 1808 | 1666 |
Test started: 2026-11-11 22:18:30
Total time taken: 11:18:40
System info: ryzen-5950x-2: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 26.04.1 LTS
OpenModelica Version: OMCompiler v1.26.9
OpenModelicaLibraryTesting Changes
| Commit | Date | Author | Summary |
|---|---|---|---|
| 1c9738a | 2026-11-11 20:56:15 +0100 | Martin Sjölund | Install a newer nightly omc in the testing image (#415) |
Tested Library: Buildings_latest 15.0.0
{
"convertFromVersion": [
"8.0.0",
"8.1.0",
"8.1.1",
"8.1.2",
"8.1.3",
"9.0.0",
"9.1.0",
"9.1.1",
"9.1.2",
"10.0.0",
"10.1.0",
"10.1.1",
"11.0.0",
"11.1.0",
"11.1.1",
"11.1.2",
"12.0.0",
"12.1.0",
"12.1.1",
"12.1.2",
"13.0.0",
"13.0.1"
],
"path": "Buildings",
"provides": [
"14.0.0"
],
"sha": "891a330d56ce6148806fe1fa90d431213ebd382e",
"support": "noSupport",
"uses": {
"Modelica": "4.1.0"
},
"version": "15.0.0-master",
"wasm": {
"2": {
"generation": 1,
"sha256": "f7a9f8aa5192b4a606ebc813f0112f93f96d5c5a3248a4f3ef3301afe333cf40",
"systemLibraries": [
"libc"
],
"zipfile": "https://libraries.openmodelica.org/precompiled/wasm32-wasip1/omc-1/Buildings-wasm32-wasip1-5ea31497e343e520.zip"
}
},
"zipfile": "https://github.com/lbl-srg/modelica-buildings/archive/891a330d56ce6148806fe1fa90d431213ebd382e.zip"
}
BuildModel time limit: 300s
Simulation time limit: 240s
Simulation time limit for Buildings.DHC.Examples.Combined.SeriesConstantFlow: 780s
Simulation time limit for Buildings.DHC.Examples.Combined.SeriesVariableFlow: 810s
Simulation time limit for Buildings.Examples.DualFanDualDuct.ClosedLoop: 390s
Simulation time limit for Buildings.Examples.VAVReheat.Guideline36: 330s
Simulation time limit for Buildings.Fluid.Geothermal.ZonedBorefields.Examples.SeriesConnectedZones: 360s
Simulation time limit for Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring: 450s
Simulation time limit for Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Summer: 420s
Simulation time limit for Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Winter: 600s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default
Reference Files: /mnt/ReferenceFiles/Buildings/csv/master
commit 3e2dfaf9aef8b68f43600e414777bd8e269f9f5e Date: Thu Nov 5 14:52:51 2026 -0800 Merge pull request #4855 from lbl-srg/issue4845_correctMedium Correct condenser water pump mediumVerified using: v1.28.0-dev.1860+ge89ef0a.cmake (diffSimulationResults)
Flags:setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config: {
"environmentSimulation": [
[
"SPAWNPATH",
"$libraryLocation/Resources/bin/Spawn-light-*/linux64/bin"
]
],
"ignoreModelPrefix": [
"Buildings.Utilities.IO.BCVTB.Examples",
"Buildings.Obsolete"
],
"library": "Buildings",
"libraryVersion": "master",
"libraryVersionNameForTests": "latest",
"referenceFileExtension": "csv",
"referenceFileNameDelimiter": "_",
"referenceFilePreprocessor": "quoteCsvHeader",
"referenceFiles": "/mnt/ReferenceFiles/Buildings/csv/master",
"runOnceBeforeTesting": [
[
"$resourceLocation/src/ThermalZones/install.py",
"--binaries-for-os-only"
]
],
"ulimitExeModels": {
"Buildings.DHC.Examples.Combined.SeriesConstantFlow": 780,
"Buildings.DHC.Examples.Combined.SeriesVariableFlow": 810,
"Buildings.Examples.DualFanDualDuct.ClosedLoop": 390,
"Buildings.Examples.VAVReheat.Guideline36": 330,
"Buildings.Fluid.Geothermal.ZonedBorefields.Examples.SeriesConnectedZones": 360,
"Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring": 450,
"Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Summer": 420,
"Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Winter": 600
},
"ulimitOmc": 300
}
Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.