Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating_Autosizing -abortSlowSimulation -alarm=240 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.10.20 12:34 Initializing Response Factors Calculating CTFs for "CEILING:GARAGE" Calculating CTFs for "CEILING:LIVING" Calculating CTFs for "EXTWALL:GARAGE" Calculating CTFs for "EXTWALL:LIVING" Calculating CTFs for "FLOOR:GARAGE" Calculating CTFs for "FLOOR:LIVING" Calculating CTFs for "GABLE" Calculating CTFs for "GARAGE:STEELDOOR" Calculating CTFs for "INTERIORWALL" Calculating CTFs for "ROOF" Initializing Window Optical Properties Initializing Solar Calculations Allocate Solar Module Arrays Initializing Zone and Enclosure Report Variables Initializing Surface (Shading) Report Variables Determining Shadowing Combinations Computing Window Shade Absorption Factors Proceeding with Initializing Solar Calculations Initializing Surfaces Initializing Outdoor environment for Surfaces Setting up Surface Reporting Variables Initializing Temperature and Flux Histories Initializing Window Shading Computing Interior Absorption Factors Computing Interior Diffuse Solar Absorption Factors Initializing Solar Heat Gains Initializing Internal Heat Gains Initializing Interior Solar Distribution Initializing Interior Convection Coefficients Gathering Information for Predefined Reporting Completed Initializing Surface Heat Balance Calculate Outside Surface Heat Balance Calculate Inside Surface Heat Balance Calculate Air Heat Balance Initializing HVAC Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #1 CHICAGO_IL_USA ANNUAL COOLING 1% DESIGN CONDITIONS DB/MCWB Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #2 CHICAGO_IL_USA ANNUAL HEATING 99% DESIGN CONDITIONS DB Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59403e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0229069s reading init.xml | | | | | | 0.00158665s reading info.xml | | | | | | 9.2484e-05s [ 0.0%] pre-initialization | | | | | | 7.53132s [ 97.7%] initialization | | | | | | 9.668e-06s [ 0.0%] steps | | | | | | 0.0117895s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0788459s [ 1.0%] event-handling | | | | | | 0.00669889s [ 0.1%] overhead | | | | | | 0.0791805s [ 1.0%] simulation | | | | | | 7.70794s [100.0%] total | | | | | events | | | | | | 226 state events | | | | | | 2 time events | | | | | solver: dassl | | | | | | 9342 steps taken | | | | | | 14556 calls of functionODE | | | | | | 5361 evaluations of jacobian | | | | | | 670 error test failures | | | | | | 310 convergence test failures | | | | | | 0.0424267s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.66sec EnergyPlus Completed Successfully.