Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 1245 * Number of variables: 1245 Warning: Deprecated debug flag -d=disablePartitioning detected. Use --preOptModules-=clockPartitioning instead. Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 230 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (484): * Single equations (assignments): 480 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 3 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details: * Constant Jacobian: 0 * Linear Jacobian (size,density): 0 * Non-linear Jacobian: 3 {1,1,1} * Without analytic Jacobian: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 0 * Non-linear torn systems: 1 {32 300} Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 1 * Number of states: 38 (Plant.Boiler.WaterSide.p,Plant.Boiler.WaterSide.htilde[1],Plant.Boiler.WaterSide.htilde[2],Plant.Boiler.WaterSide.htilde[3],Plant.Boiler.WaterSide.htilde[4],Plant.Boiler.WaterSide.htilde[5],Plant.Boiler.WaterSide.htilde[6],Plant.Boiler.WaterSide.htilde[7],Plant.Boiler.WaterSide.htilde[8],Plant.Boiler.WaterSide.htilde[9],Plant.Boiler.WaterSide.htilde[10],Plant.Boiler.TubeWalls.Tvol[1],Plant.Boiler.TubeWalls.Tvol[2],Plant.Boiler.TubeWalls.Tvol[3],Plant.Boiler.TubeWalls.Tvol[4],Plant.Boiler.TubeWalls.Tvol[5],Plant.Boiler.TubeWalls.Tvol[6],Plant.Boiler.TubeWalls.Tvol[7],Plant.Boiler.TubeWalls.Tvol[8],Plant.Boiler.TubeWalls.Tvol[9],Plant.Boiler.TubeWalls.Tvol[10],Plant.Boiler.GasSide.Ttilde[1],Plant.Boiler.GasSide.Ttilde[2],Plant.Boiler.GasSide.Ttilde[3],Plant.Boiler.GasSide.Ttilde[4],Plant.Boiler.GasSide.Ttilde[5],Plant.Boiler.GasSide.Ttilde[6],Plant.Boiler.GasSide.Ttilde[7],Plant.Boiler.GasSide.Ttilde[8],Plant.Boiler.GasSide.Ttilde[9],Plant.Boiler.GasSide.Ttilde[10],Plant.Boiler.GasSide.p,Plant.GasFlowActuator.y,Plant.WaterInTSensor.y,Plant.WaterOutTSensor.y,Plant.GasInTSensor.y,Plant.GasOutTSensor.y,Plant.ValveOpeningActuator.y) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (445): * Single equations (assignments): 419 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 4 * Torn equation systems: 22 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details: * Constant Jacobian: 0 * Linear Jacobian (size,density): 0 * Non-linear Jacobian: 4 {1,1,1,1} * Without analytic Jacobian: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 22 {(11,62.8%) 40,(1,100.0%) 1,(10,92.0%) 21,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1,(1,100.0%) 1} * Non-linear torn systems: 0