Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 578 * Number of variables: 578 Warning: Deprecated debug flag -d=disablePartitioning detected. Use --preOptModules-=clockPartitioning instead. Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Warning: Iteration variables with default zero start attribute in torn nonlinear equation system: plant.compressor.tau:VARIABLE(unit = "N.m" ) "net torque acting on the compressor" type: Real plant.generator.tau:VARIABLE(unit = "N.m" ) "Torque at shaft" type: Real Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 40 * Number of states: 0 () * Number of discrete variables: 1 (plant.network.closedInternal) * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (151): * Single equations (assignments): 141 * Array equations: 0 * Algorithm blocks: 5 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 4 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details: * Constant Jacobian: 0 * Linear Jacobian (size,density): 0 * Non-linear Jacobian: 4 {1,1,1,1} * Without analytic Jacobian: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 0 * Non-linear torn systems: 1 {15 52} Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 1 * Number of states: 14 (plant.generator.omega_m,plant.generator.shaft.phi,plant.network.delta,plant.CombustionChamber1.fluegas.p,plant.CombustionChamber1.fluegas.Xi[2],plant.CombustionChamber1.fluegas.Xi[3],plant.CombustionChamber1.fluegas.Xi[4],plant.CombustionChamber1.fluegas.Xi[5],plant.CombustionChamber1.fluegas.T,plant.CombustionChamber1.fluegas.R,plant.CombustionChamber1.Tm,plant.gasFlowActuator.y,plant.powerSensor1.y,pID.I) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (131): * Single equations (assignments): 123 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 5 * Torn equation systems: 3 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details: * Constant Jacobian: 0 * Linear Jacobian (size,density): 0 * Non-linear Jacobian: 5 {1,1,1,1,1} * Without analytic Jacobian: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 1 {(1,100.0%) 1} * Non-linear torn systems: 2 {3 8,1 4}