To simulate FMU `TriggeredSubsystems_sf.fmu` with OMSimulator run ```bash $ wine64 /var/lib/jenkins/ws/Sandbox/Andreas/OMSimulator-FMI-Cross-Check/OMSimulatorBinaries/OMSimulator-mingw64/bin/OMSimulator.exe --stripRoot=true --skipCSVHeader=true --addParametersToCSV=true --intervals=500 --suppressPath=true --timeout=60 TriggeredSubsystems_sf.lua ``` Lua file: ```lua -- Lua file for TriggeredSubsystems_sf.fmu oms_setTempDirectory("temp") oms_newModel("model") oms_addSystem("model.root", oms_system_wc) -- instantiate FMU oms_addSubModel("model.root.fmu", "../../../../../../../../../fmus/2.0/cs/win64/DS_FMU_Export_from_Simulink/2.1.1/TriggeredSubsystems_sf/TriggeredSubsystems_sf.fmu") -- Simulation settings oms_setResultFile("model", "TriggeredSubsystems_sf_out.csv") oms_setStartTime("model", 0.0) oms_setStopTime("model", 10.0) oms_setTolerance("model", 0.001) initialStepSize, minimumStepSize, maximumStepSize, status = oms_getVariableStepSize("model") oms_setVariableStepSize("model", 0.001, minimumStepSize, 0.001) oms_setFixedStepSize("model", 0.001) -- Instantiate, initialize and simulate oms_instantiate("model") oms_initialize("model") oms_simulate("model") oms_terminate("model") oms_delete("model") ``` See the [OMSimulator documentation](https://openmodelica.org/doc/OMSimulator/master/html/index.html) for more information.
Stdout:
info: 0 warnings info: 3 errors warning: temp directory "Z:\var\lib\jenkins\ws\Sandbox\Andreas\OMSimulator-FMI-Cross-Check\OMSimulator\testsuite\fmi-cross-check\fmi-cross-check\results\2.0\cs\win64\OMSimulator\v2.1.1\DS_FMU_Export_from_Simulink\2.1.1\TriggeredSubsystems_sf\temp\model-fckq1ls1" couldn't be removed filesystem error: cannot remove all: Input/output error [Z:\var\lib\jenkins\ws\Sandbox\Andreas\OMSimulator-FMI-Cross-Check\OMSimulator\testsuite\fmi-cross-check\fmi-cross-check\results\2.0\cs\win64\OMSimulator\v2.1.1\DS_FMU_Export_from_Simulink\2.1.1\TriggeredSubsystems_sf\temp\model-fckq1ls1] [Z:\var\lib\jenkins\ws\Sandbox\Andreas\OMSimulator-FMI-Cross-Check\OMSimulator\testsuite\fmi-cross-check\fmi-cross-check\results\2.0\cs\win64\OMSimulator\v2.1.1\DS_FMU_Export_from_Simulink\2.1.1\TriggeredSubsystems_sf\temp\model-fckq1ls1\temp\0001_fmu\binaries\win64]
Stderr:
error: [fmiLogger] module FMILIB: Directory path for FMU is too long error: [NewComponent] Error parsing modelDescription.xml error: [oms_RunFile] TriggeredSubsystems_sf.lua:7: oms_addSubModel(model.root.fmu,../../../../../../../../../fmus/2.0/cs/win64/DS_FMU_Export_from_Simulink/2.1.1/TriggeredSubsystems_sf/TriggeredSubsystems_sf.fmu) failed