startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 wasm-jit simulation: simulate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7",simflags="-abortSlowSimulation -alarm=570 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/CentrifugalPump.mo:43:3-43:45:writable] | | | | The following assertion has been violated at time 0.004935 | | | | ((centrifugalPump.hn >= 0.0)) --> "Variable violating min constraint: 0.0 <= centrifugalPump.hn, has value: -9.17807" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 6.3901e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.100807s [ 0.1%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.286502s [ 0.3%] solver (excl. callbacks) LOG_STATS | info | | 0.00617684s [ 0.0%] creating output-file LOG_STATS | info | | 29.8932s [ 34.3%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 56.8307s [ 65.2%] simulation LOG_STATS | info | | 87.1175s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 18 state events LOG_STATS | info | | 3 time events LOG_STATS | info | solver: LOG_STATS | info | | 213205 steps taken LOG_STATS | info | | 265563 calls of functionODE LOG_STATS | info | | 10796 evaluations of jacobian LOG_STATS | info | | 7991 error test failures LOG_STATS | info | | 2 convergence test failures LOG_STATS | info | | 9.38848s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.