Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.Simulators.CCPP_Sim3.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real [:1:1-1:33:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0002855/0.0002855, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0003384/0.0003384, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 0.2128/0.2128, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/package.mo): time 0.04481/0.04481, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: simulate(ThermoPower.PowerPlants.Simulators.CCPP_Sim3,startTime=0,stopTime=7000,tolerance=1e-06,numberOfIntervals=3000,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.Simulators.CCPP_Sim3",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") simulate(ThermoPower.PowerPlants.Simulators.CCPP_Sim3,startTime=0,stopTime=7000,tolerance=1e-06,numberOfIntervals=3000,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.Simulators.CCPP_Sim3",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 7.01e-07/7.01e-07, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 1.357e-05/1.428e-05, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Sources.mo:388:5-389:46:writable] Warning: Parameter valveHP_com.duration has no value, and is fixed during initialization (fixed=true), using available start value (start=2) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Sources.mo:388:5-389:46:writable] Warning: Parameter valveIP_com.duration has no value, and is fixed during initialization (fixed=true), using available start value (start=2) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Sources.mo:388:5-389:46:writable] Warning: Parameter valveLP_com.duration has no value, and is fixed during initialization (fixed=true), using available start value (start=2) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/PowerPlants.mo:17812:11-17812:20:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower master/package.mo:145:5-145:107:writable] Error: Trying to override final element J with modifier '= J_shaft'. Notification: Performance of FrontEnd: time 0.6486/0.6486, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 899] [Calling sys.exit(0), Time elapsed: 1.6726446687243879]