Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.recompPB.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real [:1:1-1:33:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.000302/0.000302, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0004122/0.0004122, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 0.2239/0.2239, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo): time 0.03397/0.03397, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/Utilities/LinProgFunc.mo:6:1-33:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 180] Using package SolarTherm with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: simulate(SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.recompPB,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=500,outputFormat="empty",variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.recompPB",simflags="-lv=LOG_STATS -outputFormat=mat -s=dassl -abortSlowSimulation -alarm=240 -lv LOG_STATS") simulate(SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.recompPB,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=500,outputFormat="empty",variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.recompPB",simflags="-lv=LOG_STATS -outputFormat=mat -s=dassl -abortSlowSimulation -alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 5.21e-07/5.21e-07, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 9.037e-06/9.558e-06, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/Models/PowerBlocks/sCO2Cycle/OffDesign/recompPB.mo:33:3-33:181:writable] Error: Class SolarTherm.Types.Conductance not found in scope recompPB. Notification: Performance of FrontEnd: time 0.004634/0.004644, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 900] [Calling sys.exit(0), Time elapsed: 1.033543056808412]