startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=50000 stepSize=0.0002 wasm-jit simulation: simulate(Modelica.Electrical.PowerConverters.Examples.ACAC.SoftStarter,startTime=0,stopTime=10,tolerance=1e-06,numberOfIntervals=50000,outputFormat="mat",variableFilter="time|currentQuasiRMSSensor.i.[0-9,]+.|voltageSensor.v.[0-9,]+.|multiSensor.i.[0-9,]+.|multiSensor.v.[0-9,]+.|multiSensor.power.[0-9,]+.|multiSensor.powerTotal|rootMeanSquare.y|rootMeanSquare.mean.x|harmonic.mean1.x|harmonic.mean2.x|// imc.rotorCage.electroMagneticConverter.singlePhaseElectroMagneticConverter.[0-9,]+..Phi.re|// imc.rotorCage.electroMagneticConverter.singlePhaseElectroMagneticConverter.[0-9,]+..Phi.im|// imc.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.[0-9,]+..Phi.re|// imc.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.[0-9,]+..Phi.im|// imc.stator.zeroInductor.i0|loadInertia.phi|loadInertia.w|softStartControl.vRef",fileNamePrefix="Modelica_trunk_Modelica.Electrical.PowerConverters.Examples.ACAC.SoftStarter",simflags="-abortSlowSimulation -alarm=510 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/PowerConverters/ACAC/Control/SoftStartControl.mo:15:3-17:54:writable] | | | | The following assertion has been violated at time 4.508187 | | | | ((softStartControl.vRef >= 0.0 and softStartControl.vRef <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= softStartControl.vRef <= 1.0, has value: 1" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 7.1985e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.000188976s [ 0.0%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 6.67499s [ 5.5%] solver (excl. callbacks) LOG_STATS | info | | 0.170348s [ 0.1%] creating output-file LOG_STATS | info | | 10.0546s [ 8.3%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 104.771s [ 86.1%] simulation LOG_STATS | info | | 121.672s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 9631 state events LOG_STATS | info | | 500 time events LOG_STATS | info | solver: LOG_STATS | info | | 2333450 steps taken LOG_STATS | info | | 5676381 calls of functionODE LOG_STATS | info | | 3236772 evaluations of jacobian LOG_STATS | info | | 2292 error test failures LOG_STATS | info | | 1047678 convergence test failures LOG_STATS | info | | 79.4311s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.