startTime=0 stopTime=3 tolerance=1e-06 numberOfIntervals=5004 stepSize=0.00059952 wasm-jit simulation: simulate(ModelicaTest.Fluid.TestPipesAndValves.DynamicPipeClosingValve,startTime=0,stopTime=3,tolerance=1e-06,numberOfIntervals=5004,outputFormat="mat",variableFilter="time|pipe.mediums.[0-9,]+..h|pipe.mediums.[0-9,]+..p",fileNamePrefix="ModelicaTest_4.1.0_ModelicaTest.Fluid.TestPipesAndValves.DynamicPipeClosingValve",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 5.338e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.000478281s [ 0.4%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000949923s [ 0.9%] solver (excl. callbacks) LOG_STATS | info | | 0.00750224s [ 6.9%] creating output-file LOG_STATS | info | | 0.0336617s [ 31.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0659791s [ 60.7%] simulation LOG_STATS | info | | 0.108625s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 301 steps taken LOG_STATS | info | | 657 calls of functionODE LOG_STATS | info | | 416 evaluations of jacobian LOG_STATS | info | | 0 error test failures LOG_STATS | info | | 117 convergence test failures LOG_STATS | info | | 0.0053322s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.