startTime=0 stopTime=11 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0044 wasm-jit simulation: simulate(HelmholtzMedia.Examples.MediaTestModels.IsobutaneTestModel,startTime=0,stopTime=11,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="HelmholtzMedia_HelmholtzMedia.Examples.MediaTestModels.IsobutaneTestModel",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Media/package.mo:3398:9-3401:32:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fixedMassFlowRate.h_ambient >= -725000.0 and fixedMassFlowRate.h_ambient <= 7e5)) --> "Variable violating min/max constraint: -725000.0 <= fixedMassFlowRate.h_ambient <= 7e5, has value: 707544" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 4.8561e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.107305s [ 4.5%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000523225s [ 0.0%] solver (excl. callbacks) LOG_STATS | info | | 0.00217349s [ 0.1%] creating output-file LOG_STATS | info | | 1.20706s [ 50.5%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 1.07331s [ 44.9%] simulation LOG_STATS | info | | 2.39042s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 104 steps taken LOG_STATS | info | | 135 calls of functionODE LOG_STATS | info | | 22 evaluations of jacobian LOG_STATS | info | | 3 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.0157952s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.