startTime=0 stopTime=6000 tolerance=1e-06 numberOfIntervals=2500 stepSize=2.4 wasm-jit simulation: simulate(Buildings.Fluid.Boilers.Examples.BoilerTable,startTime=0,stopTime=6000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|boi1.sta_a.T|boi1.sta_b.T|boi2.sta_b.T|boi1.eta|boi2.eta|y.y",fileNamePrefix="Buildings_latest_Buildings.Fluid.Boilers.Examples.BoilerTable",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 0.000141256s [ 1.5%] pre-initialization LOG_STATS | info | | 0.000282862s [ 3.0%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000547481s [ 5.7%] solver (excl. callbacks) LOG_STATS | info | | 0.00147094s [ 15.4%] creating output-file LOG_STATS | info | | 0.000853755s [ 9.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00623s [ 65.4%] simulation LOG_STATS | info | | 0.0095263s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 6 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 347 steps taken LOG_STATS | info | | 470 calls of functionODE LOG_STATS | info | | 108 evaluations of jacobian LOG_STATS | info | | 12 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 4.0239e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.