startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm-jit simulation: simulate(Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|heaNoLoc.VChiWat_flow|heaNoLoc.VChiWat_flow_nominal|heaNoLoc.yChiWatPum.[0-9,]+.|heaNoLoc.dpChiWat_remote.[0-9,]+.|heaNoLoc.dpChiWatSet_remote.[0-9,]+.|heaNoLoc.yPumSpe|heaNoLoc.u1ChiWatIsoVal.[0-9,]+.|dedNoLoc.uLeaChiEna|dedNoLoc.uLeaChiSta|dedNoLoc.uLeaChiWatReq|dedNoLoc.enaDedLeaPum.yLea|dedNoLoc.dpChiWat_remote.[0-9,]+.|dedNoLoc.dpChiWatSet_remote.[0-9,]+.|dedNoLoc.yPumSpe|dedLoc.uLeaChiEna|dedLoc.uLeaChiSta|dedLoc.uLeaChiWatReq|dedLoc.dpChiWat_local|dedLoc.dpChiWatSet_local|dedLoc.yPumSpe",fileNamePrefix="Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120:3-125:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((dedLoc.yPumSpe >= max(dedLoc.pumSpeLocDp.minPumSpe, 0.0) and dedLoc.yPumSpe <= min(dedLoc.pumSpeLocDp.maxPumSpe, 1.0))) --> "Variable violating min/max constraint: max(dedLoc.pumSpeLocDp.minPumSpe, 0.0) <= dedLoc.yPumSpe <= min(dedLoc.pumSpeLocDp.maxPumSpe, 1.0), has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120:3-125:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((dedNoLoc.yPumSpe >= max(dedNoLoc.pumSpeRemDp.minPumSpe, 0.0) and dedNoLoc.yPumSpe <= min(dedNoLoc.pumSpeRemDp.maxPumSpe, 1.0))) --> "Variable violating min/max constraint: max(dedNoLoc.pumSpeRemDp.minPumSpe, 0.0) <= dedNoLoc.yPumSpe <= min(dedNoLoc.pumSpeRemDp.maxPumSpe, 1.0), has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120:3-125:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((heaNoLoc.yPumSpe >= max(heaNoLoc.pumSpeRemDp.minPumSpe, 0.0) and heaNoLoc.yPumSpe <= min(heaNoLoc.pumSpeRemDp.maxPumSpe, 1.0))) --> "Variable violating min/max constraint: max(heaNoLoc.pumSpeRemDp.minPumSpe, 0.0) <= heaNoLoc.yPumSpe <= min(heaNoLoc.pumSpeRemDp.maxPumSpe, 1.0), has value: 0" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 7.968e-05s [ 0.5%] pre-initialization LOG_STATS | info | | 0.000233178s [ 1.5%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00152729s [ 9.7%] solver (excl. callbacks) LOG_STATS | info | | 0.00581332s [ 36.8%] creating output-file LOG_STATS | info | | 0.00170278s [ 10.8%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00644134s [ 40.8%] simulation LOG_STATS | info | | 0.0157976s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 13 state events LOG_STATS | info | | 6 time events LOG_STATS | info | solver: LOG_STATS | info | | 780 steps taken LOG_STATS | info | | 1199 calls of functionODE LOG_STATS | info | | 444 evaluations of jacobian LOG_STATS | info | | 69 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.000134839s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.