startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm-jit simulation: simulate(Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.Validation.Controller_UnspecifiedClimate,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|conAHU.dpDuc|conAHU.conSupFan.staPreSetRes.y|conAHU.ySupFan|conAHU.y1SupFan|conAHU.uAhuOpeMod|conAHU.TAirSup|conAHU.TAirSupSet|conAHU.TOut|conAHU.ecoCon.uTSup|conAHU.yHeaCoi|conAHU.yCooCoi|conAHU.yOutDam|conAHU.yRetDam",fileNamePrefix="Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.Validation.Controller_UnspecifiedClimate",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not conAHU.ecoCon.ecoHigLim.noTit24Cli.k)) --> "Warning: Climate zone is not specified!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not conAHU.ecoCon.ecoHigLim.noTit24Cli.k)) --> "Warning: Climate zone is not specified!" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 6.7056e-05s [ 0.3%] pre-initialization LOG_STATS | info | | 0.000158268s [ 0.7%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00247485s [ 10.7%] solver (excl. callbacks) LOG_STATS | info | | 0.00893358s [ 38.5%] creating output-file LOG_STATS | info | | 0.00297711s [ 12.8%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00859592s [ 37.0%] simulation LOG_STATS | info | | 0.0232068s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 25 state events LOG_STATS | info | | 33 time events LOG_STATS | info | solver: LOG_STATS | info | | 1088 steps taken LOG_STATS | info | | 1306 calls of functionODE LOG_STATS | info | | 794 evaluations of jacobian LOG_STATS | info | | 24 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.000240962s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.