startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm-jit simulation: simulate(Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.FreezeProtection,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|frePro.uOutDamPosMin|frePro.uOutDam|frePro.yOutDam|frePro.uHeaCoi|frePro.yHeaCoi|frePro.yCooCoi|frePro.uRetDam|frePro.yRetDam|frePro.uSupFan|frePro.ySupFan|frePro.yAla|frePro.yHotWatPlaReq|frePro.TAirSup|frePro.yFreProSta|frePro.u1SofSwiRes",fileNamePrefix="Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.FreezeProtection",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 2730.000050 | | | | ((not frePro.lat2.y)) --> "Warning: minimum ventilation was interrupted by freeze protection!" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 3330.000050 | | | | ((not frePro.lat1.y)) --> "Warning: the unit is shut down by freeze protection!" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 6.8038e-05s [ 0.7%] pre-initialization LOG_STATS | info | | 8.0492e-05s [ 0.9%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00077219s [ 8.3%] solver (excl. callbacks) LOG_STATS | info | | 0.00211198s [ 22.8%] creating output-file LOG_STATS | info | | 0.00119528s [ 12.9%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00504129s [ 54.4%] simulation LOG_STATS | info | | 0.00926927s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 5 state events LOG_STATS | info | | 3 time events LOG_STATS | info | solver: LOG_STATS | info | | 325 steps taken LOG_STATS | info | | 404 calls of functionODE LOG_STATS | info | | 170 evaluations of jacobian LOG_STATS | info | | 17 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 3.9565e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.