startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 wasm-jit simulation: simulate(Buildings.Fluid.HeatExchangers.CoolingTowers.Validation.MerkelEnergyPlus,startTime=0,stopTime=172800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Fluid.HeatExchangers.CoolingTowers.Validation.MerkelEnergyPlus",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((dat.PFan_Q_flow_nominal >= -0.1 and dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((tow.dat.PFan_Q_flow_nominal >= -0.1 and tow.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((tow.per.dat.PFan_Q_flow_nominal >= -0.1 and tow.per.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.per.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:68:3-69:53:writable] | | | | The following assertion has been violated at time 25260.000000 | | | | ((tow.per.FRWat >= 0.0 and tow.per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.per.FRWat <= 1.0, has value: 1.0006" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 8.3297e-05s [ 0.0%] pre-initialization | | | | | | 0.00307952s [ 1.5%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.0176688s [ 8.9%] solver (excl. callbacks) | | | | | | 3.256e-06s [ 0.0%] creating output-file | | | | | | 0.0410095s [ 20.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.137186s [ 68.9%] simulation | | | | | | 0.199031s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2879 time events | | | | | solver: | | | | | | 38337 steps taken | | | | | | 45195 calls of functionODE | | | | | | 28024 evaluations of jacobian | | | | | | 323 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0358838s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.