startTime=2.592e+06 stopTime=3.6288e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=414.72 wasm-jit simulation: simulate(Buildings.DHC.Loads.Heating.Examples.BuildingTimeSeriesWithETS,startTime=2.592e+06,stopTime=3.6288e+06,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|buiWitETS.bui.loa.y.[0-9,]+.|buiWitETS.ets.Q_flow|senMasFlo.m_flow|buiWitETS.ets.senMasFlo.m_flow|buiWitETS.ets.senTDisSup.T|buiWitETS.ets.senTDisRet.T",fileNamePrefix="Buildings_12_Buildings.DHC.Loads.Heating.Examples.BuildingTimeSeriesWithETS",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 2597003.349865 | | | | ((buiWitETS.bui.terUniHea.hex.m1_flow >= 0.0 and buiWitETS.bui.terUniHea.hex.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= buiWitETS.bui.terUniHea.hex.m1_flow <= 1e5, has value: -1.54074e-33" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 2597003.349865 | | | | ((buiWitETS.bui.disFloHea.ports_a1[1].m_flow >= 0.0 and buiWitETS.bui.disFloHea.ports_a1[1].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= buiWitETS.bui.disFloHea.ports_a1[1].m_flow <= 1e5, has value: -1.64134e-31" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/DHC/Loads/BaseClasses/FlowDistribution.mo:105:3-109:84:writable] | | | | The following assertion has been violated at time 2597003.349865 | | | | ((buiWitETS.bui.disFloHea.mReq_flow[1] >= 0.0 and buiWitETS.bui.disFloHea.mReq_flow[1] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= buiWitETS.bui.disFloHea.mReq_flow[1] <= 1e5, has value: -1.64134e-31" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 2597003.349865 | | | | ((buiWitETS.bui.disFloHea.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiWitETS.bui.disFloHea.pumFlo.etaHyd, has value: -1.11341e-32" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 7.3248e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.0111043s [ 3.9%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.0142674s [ 5.0%] solver (excl. callbacks) LOG_STATS | info | | 0.00621176s [ 2.2%] creating output-file LOG_STATS | info | | 0.00709695s [ 2.5%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.245602s [ 86.4%] simulation LOG_STATS | info | | 0.284356s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 24 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 8394 steps taken LOG_STATS | info | | 13701 calls of functionODE LOG_STATS | info | | 1385 evaluations of jacobian LOG_STATS | info | | 616 error test failures LOG_STATS | info | | 22 convergence test failures LOG_STATS | info | | 0.0231937s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.