startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|ctl.u_m|ctl.u_s|con.val.y_actual|T1Sup.T|con.T2Sup.T|T1Ret.T|con.T2Ret.T|T1ConRet.T|pum.m_flow|con.pum.m_flow|con.res3.m_flow|mPum_flow_nominal|con.mPum_flow_nominal|pum.dpMachine|dp.p_rel|con.val.dp|mode.y.[0-9,]+.|fraLoa.y.[0-9,]+.|loa.yLoa_actual|loa1.yLoa_actual|loa.con.val.y_actual|loa1.con.val.y_actual",fileNamePrefix="Buildings_11_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -3.92837e-38" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.pum.pumSpe.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.heaDis.etaHyd, has value: -1.76998e-34" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -2.22833e-31" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -2.20857e-31" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Integers/Sources/TimeTable.mo:14:3-16:72:writable] | | | | The following assertion has been violated at time 21600.000000 | | | | ((mode.y[1] >= 0 and mode.y[1] <= 1)) --> "Variable violating min/max constraint: 0 <= mode.y[1] <= 1, has value: 2" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((pum.pumDp.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumDp.eff.yMot, has value: -8.86826e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -1.22268e-28" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 80559.360000 | | | | ((pum.pumDp.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumDp.etaHyd, has value: -4.34232e-26" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 7.6043e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.00100917s [ 0.5%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.0231475s [ 11.4%] solver (excl. callbacks) LOG_STATS | info | | 0.0190444s [ 9.3%] creating output-file LOG_STATS | info | | 0.00264823s [ 1.3%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.157815s [ 77.5%] simulation LOG_STATS | info | | 0.20374s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 8 state events LOG_STATS | info | | 5 time events LOG_STATS | info | solver: LOG_STATS | info | | 4015 steps taken LOG_STATS | info | | 5555 calls of functionODE LOG_STATS | info | | 571 evaluations of jacobian LOG_STATS | info | | 240 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.0467172s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.