startTime=0 stopTime=1500 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.6 wasm-jit simulation: simulate(Buildings.Fluid.CHPs.BaseClasses.Validation.EngineTemperature,startTime=0,stopTime=1500,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|eng.TRoo.T|eng.TWat.T|eng.QGen_flow|per.capEng|eng.TEng",fileNamePrefix="Buildings_11_Buildings.Fluid.CHPs.BaseClasses.Validation.EngineTemperature",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 8.3828e-05s [ 1.2%] pre-initialization LOG_STATS | info | | 7.2276e-05s [ 1.1%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000576515s [ 8.6%] solver (excl. callbacks) LOG_STATS | info | | 0.000371586s [ 5.5%] creating output-file LOG_STATS | info | | 0.00100295s [ 14.9%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00463505s [ 68.7%] simulation LOG_STATS | info | | 0.0067422s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 131 steps taken LOG_STATS | info | | 164 calls of functionODE LOG_STATS | info | | 47 evaluations of jacobian LOG_STATS | info | | 2 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 1.4617e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.