startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 wasm-jit simulation: simulate(BuildingSystems.Fluid.Geothermal.Aquifer.Validation.SimulationTest,startTime=0,stopTime=3.1536e+07,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Geothermal.Aquifer.Validation.SimulationTest",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 12614.400000 | | | | ((aquWel.pumCol.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumCol.etaHyd, has value: -0.0239763" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 12614.400000 | | | | ((aquWel.pumCol.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumCol.heaDis.etaHyd, has value: -6.4348" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 10369036.800000 | | | | ((aquWel.pumHot.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumHot.etaHyd, has value: -5.1732e-34" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 10369036.800000 | | | | ((aquWel.pumHot.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumHot.heaDis.etaHyd, has value: -1.38839e-31" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 10381651.200000 | | | | ((aquWel.pumHot.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumHot.eff.yMot, has value: -2.02455e-53" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 25935206.400000 | | | | ((aquWel.pumCol.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel.pumCol.eff.yMot, has value: -1.14775e-54" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 0.000213703s [ 0.0%] pre-initialization LOG_STATS | info | | 0.00765402s [ 0.6%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.23339s [ 19.1%] solver (excl. callbacks) LOG_STATS | info | | 0.169627s [ 13.9%] creating output-file LOG_STATS | info | | 0.00433889s [ 0.4%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.805788s [ 66.0%] simulation LOG_STATS | info | | 1.22101s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 3 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 917 steps taken LOG_STATS | info | | 1192 calls of functionODE LOG_STATS | info | | 127 evaluations of jacobian LOG_STATS | info | | 16 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.0470684s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.