startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 wasm-jit simulation: simulate(BuildingSystems.Fluid.Geothermal.Aquifer.Validation.NumberWells,startTime=0,stopTime=3.1536e+07,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Geothermal.Aquifer.Validation.NumberWells",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 12614.400000 | | | | ((aquWel1.pumHot.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel1.pumHot.etaHyd, has value: -0.0239765" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 12614.400000 | | | | ((aquWel1.pumHot.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel1.pumHot.heaDis.etaHyd, has value: -1.25945" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 12614.400000 | | | | ((aquWel2.pumHot.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel2.pumHot.etaHyd, has value: -0.0239765" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 12614.400000 | | | | ((aquWel2.pumHot.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= aquWel2.pumHot.heaDis.etaHyd, has value: -1.25945" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 0.000103945s [ 0.0%] pre-initialization LOG_STATS | info | | 0.0031255s [ 1.3%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.222765s [ 92.4%] solver (excl. callbacks) LOG_STATS | info | | 0.0791312s [ 32.8%] creating output-file LOG_STATS | info | | 0s [ 0.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | -0.0640826s [-26.6%] simulation LOG_STATS | info | | 0.241043s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 196 steps taken LOG_STATS | info | | 242 calls of functionODE LOG_STATS | info | | 33 evaluations of jacobian LOG_STATS | info | | 3 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.00284138s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.