startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(BuildingSystems.Buildings.Constructions.Examples.Door,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Buildings.Constructions.Examples.Door",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/weather/USA_SanFrancisco.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Airflow/Multizone/MediumColumn.mo:10:3-10:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zone.airpath[1].h >= 0.0)) --> "Variable violating min constraint: 0.0 <= zone.airpath[1].h, has value: -0.9" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:16:3-17:24:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ambience.weatherDataReader.weatherData.phiAir >= 0.0 and ambience.weatherDataReader.weatherData.phiAir <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= ambience.weatherDataReader.weatherData.phiAir <= 1.0, has value: 1.0225" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 0.000132439s [ 0.1%] pre-initialization LOG_STATS | info | | 0.0173056s [ 11.0%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.0119138s [ 7.6%] solver (excl. callbacks) LOG_STATS | info | | 0.00547738s [ 3.5%] creating output-file LOG_STATS | info | | 0.040762s [ 25.8%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0821317s [ 52.1%] simulation LOG_STATS | info | | 0.157723s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 97 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 8687 steps taken LOG_STATS | info | | 13006 calls of functionODE LOG_STATS | info | | 2176 evaluations of jacobian LOG_STATS | info | | 473 error test failures LOG_STATS | info | | 75 convergence test failures LOG_STATS | info | | 0.0284914s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.