startTime=0 stopTime=1000 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.4 wasm-jit simulation: simulate(BuildSysPro.IBPSA.Fluid.Movers.Validation.Pump_Nrpm_stratos,startTime=0,stopTime=1000,tolerance=1e-08,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.Pump_Nrpm_stratos",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump1: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump1: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump2: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump2: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump3.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump3: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump3: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump4.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump4: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump4: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump5.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump5: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Pump_Nrpm_stratos.forcedPump5: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump1.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump1.heaDis.etaHyd, has value: -46.5769" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:301:3-305:28:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump1.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump1.eff.yMot, has value: -1.28809e-05" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump2.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump2.heaDis.etaHyd, has value: -40.436" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:301:3-305:28:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump2.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump2.eff.yMot, has value: -1.11826e-05" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump3.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump3.heaDis.etaHyd, has value: -25.8585" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:301:3-305:28:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump3.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump3.eff.yMot, has value: -7.15122e-06" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump4.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump4.heaDis.etaHyd, has value: -50.7259" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:301:3-305:28:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump4.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump4.eff.yMot, has value: -1.40283e-05" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump5.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump5.heaDis.etaHyd, has value: -6.40573" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:301:3-305:28:writable] | | | | The following assertion has been violated at time 100.400000 | | | | ((forcedPump5.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= forcedPump5.eff.yMot, has value: -1.77152e-06" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 9.7764e-05s [ 0.4%] pre-initialization LOG_STATS | info | | 0.000923568s [ 4.0%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00244497s [ 10.6%] solver (excl. callbacks) LOG_STATS | info | | 0.00761582s [ 33.1%] creating output-file LOG_STATS | info | | 0.00103989s [ 4.5%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0108837s [ 47.3%] simulation LOG_STATS | info | | 0.0230057s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 695 steps taken LOG_STATS | info | | 940 calls of functionODE LOG_STATS | info | | 176 evaluations of jacobian LOG_STATS | info | | 54 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 9.7763e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.