startTime=0 stopTime=172800 tolerance=1e-08 numberOfIntervals=2500 stepSize=69.12 wasm-jit simulation: simulate(BuildSysPro.IBPSA.Fluid.HeatExchangers.Examples.AirHeater_T,startTime=0,stopTime=172800,tolerance=1e-08,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatExchangers.Examples.AirHeater_T",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in AirHeater_T.mov: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in AirHeater_T.mov: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 5.5885e-05s [ 0.3%] pre-initialization LOG_STATS | info | | 0.000217029s [ 1.2%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.0051107s [ 28.4%] solver (excl. callbacks) LOG_STATS | info | | 0.00199572s [ 11.1%] creating output-file LOG_STATS | info | | 0.00210437s [ 11.7%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00852942s [ 47.4%] simulation LOG_STATS | info | | 0.0180131s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 4 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 4371 steps taken LOG_STATS | info | | 6090 calls of functionODE LOG_STATS | info | | 887 evaluations of jacobian LOG_STATS | info | | 344 error test failures LOG_STATS | info | | 3 convergence test failures LOG_STATS | info | | 0.00126851s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.