startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.24 wasm-jit simulation: simulate(AixLib.Systems.HydraulicModules.Examples.ThrottlePump,startTime=0,stopTime=600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Systems.HydraulicModules.Examples.ThrottlePump",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6:3-7:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eff.powEu.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7:3-8:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eta, has value: -6.24167e-45" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.heaDis.etaHyd, has value: -5.23423e-42" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.yMot, has value: -6.9625e-47" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 6.4702e-05s [ 0.3%] pre-initialization LOG_STATS | info | | 0.000648932s [ 2.8%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00243131s [ 10.6%] solver (excl. callbacks) LOG_STATS | info | | 0.00649935s [ 28.3%] creating output-file LOG_STATS | info | | 0.000815151s [ 3.5%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0125103s [ 54.5%] simulation LOG_STATS | info | | 0.0229697s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 1 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 269 steps taken LOG_STATS | info | | 433 calls of functionODE LOG_STATS | info | | 59 evaluations of jacobian LOG_STATS | info | | 10 error test failures LOG_STATS | info | | 5 convergence test failures LOG_STATS | info | | 0.000953528s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.