startTime=0 stopTime=800 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.32 wasm-jit simulation: simulate(AixLib.Systems.HydraulicModules.Examples.Injection2WayValve,startTime=0,stopTime=800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Systems.HydraulicModules.Examples.Injection2WayValve",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6:3-7:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eff.powEu.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7:3-8:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eta, has value: -7.78347e-31" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.heaDis.etaHyd, has value: -6.52717e-28" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.yMot, has value: -8.68236e-33" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 680.640000 | | | | ((Injection.valve.actPos.y >= 0.0 and Injection.valve.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= Injection.valve.actPos.y <= 1.0, has value: 1" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 7.3809e-05s [ 0.2%] pre-initialization LOG_STATS | info | | 0.000724244s [ 2.1%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00442525s [ 13.0%] solver (excl. callbacks) LOG_STATS | info | | 0.0106823s [ 31.3%] creating output-file LOG_STATS | info | | 0.000897834s [ 2.6%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0173472s [ 50.8%] simulation LOG_STATS | info | | 0.0341506s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: LOG_STATS | info | | 285 steps taken LOG_STATS | info | | 485 calls of functionODE LOG_STATS | info | | 71 evaluations of jacobian LOG_STATS | info | | 13 error test failures LOG_STATS | info | | 4 convergence test failures LOG_STATS | info | | 0.00163933s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.