startTime=0 stopTime=150 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.06 wasm-jit simulation: simulate(ThermofluidStream.Topology.Tests.TestNonPhysical,startTime=0,stopTime=150,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="Time|junctionRatio1.outlet.m_flow|junctionRatio1.splitRatioLim|junctionRatio2.outlet.m_flow|junctionRatio2.splitRatioLim|leakageA.dp|leakageA.inlet.m_flow|leakageA.splitRatioLim|leakageA1.dp|leakageA1.inlet.m_flow|leakageA1.splitRatioLim|rTSwitch.dp|rTSwitch.inlet.m_flow|rTSwitch.splitRatioLim|rTSwitch1.dp|rTSwitch1.inlet.m_flow|rTSwitch1.splitRatioLim|ratioControl.dp|ratioControl.inlet.m_flow|ratioControl.splitRatioLim|ratioControl1.dp|ratioControl1.inlet.m_flow|ratioControl1.splitRatioLim|timeTable.a|timeTable.b|timeTable.last|timeTable.nextEvent|timeTable.nextEventScaled",fileNamePrefix="ThermofluidStream_dev_ThermofluidStream.Topology.Tests.TestNonPhysical",simflags="-alarm=1200 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Topology/Internal.mo:79:5-81:30:writable] | | | | The following assertion has been violated at time 0.060000 | | | | ((ratioControl1.P_B < ratioControl1.P_thresh)) --> "Splitter enforces mass flow constraint by artificially increasing pressure on outlet B" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Topology/Internal.mo:79:5-81:30:writable] | | | | The following assertion has been violated at time 0.120000 | | | | ((ratioControl.P_B < ratioControl.P_thresh)) --> "Splitter enforces mass flow constraint by artificially increasing pressure on outlet B" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Topology/Internal.mo:79:5-81:30:writable] | | | | The following assertion has been violated at time 10.980000 | | | | ((rTSwitch1.P_B < rTSwitch1.P_thresh)) --> "Splitter enforces mass flow constraint by artificially increasing pressure on outlet B" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Topology/Internal.mo:75:5-77:30:writable] | | | | The following assertion has been violated at time 97.320000 | | | | ((leakageA1.P_A < leakageA1.P_thresh)) --> "Splitter enforces mass flow constraint by artificially increasing pressure on outlet A" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 13 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 1982 steps taken LOG_STATS | info | | 2879 calls of functionODE LOG_STATS | info | | 410 evaluations of jacobian LOG_STATS | info | | 104 error test failures LOG_STATS | info | | 1 convergence test failures LOG_STATS | info | | 101780 linear system solves LOG_SUCCESS | info | The simulation finished successfully.