startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.001 wasm-jit simulation: simulate(ThermofluidStream.Interfaces.Tests.Test_p_out_clipping,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=1000,outputFormat="mat",variableFilter="Time|basicControlValve.m_flow|fan.m_flow|fan.omega|fan.phi|flowResistance.m_flow|nozzle.m_flow|specificValveType.m_flow|tanValve.m_flow",fileNamePrefix="ThermofluidStream_ThermofluidStream.Interfaces.Tests.Test_p_out_clipping",simflags="-alarm=1200 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sink.inlet.state.T >= 273.15 and sink.inlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= sink.inlet.state.T <= 373.15, has value: 174.876" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((junctionN.inlets[4].state.T >= 273.15 and junctionN.inlets[4].state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= junctionN.inlets[4].state.T <= 373.15, has value: -46.4042" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((junctionN.inlets[5].state.T >= 273.15 and junctionN.inlets[5].state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= junctionN.inlets[5].state.T <= 373.15, has value: 146.574" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Topology/JunctionN.mo:28:3-28:82:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((junctionN.rho[4] >= 0.0 and junctionN.rho[4] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= junctionN.rho[4] <= 1e5, has value: -0.0075073" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Topology/JunctionN.mo:28:3-28:82:writable] | | | | The following assertion has been violated at time 0.005000 | | | | ((junctionN.rho[5] >= 0.0 and junctionN.rho[5] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= junctionN.rho[5] <= 1e5, has value: 101920" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 584 steps taken LOG_STATS | info | | 762 calls of functionODE LOG_STATS | info | | 97 evaluations of jacobian LOG_STATS | info | | 16 error test failures LOG_STATS | info | | 9 convergence test failures LOG_STATS | info | | 2444 linear system solves LOG_SUCCESS | info | The simulation finished successfully.