startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.2 wasm-jit simulation: simulate(ThermofluidStream.Examples.ReverseHeatPump,startTime=0,stopTime=200,tolerance=1e-06,numberOfIntervals=1000,outputFormat="mat",variableFilter="PI1.x|PI2.x|PI_Valve.x|TEVcooling.rear.m_flow|Time|accumulator.M|accumulator.U_med|accumulator.m_flow_in|boundaryFore1.rear.m_flow|boundaryRear.fore.m_flow|compressor.m_flow|discretizedHEX.thermalElementA.1..h|discretizedHEX.thermalElementA.2..h|discretizedHEX.thermalElementA.3..h|discretizedHEX.thermalElementA.4..h|discretizedHEX.thermalElementA.5..h|discretizedHEX.thermalElementB.1..h|discretizedHEX.thermalElementB.2..h|discretizedHEX.thermalElementB.3..h|discretizedHEX.thermalElementB.4..h|discretizedHEX.thermalElementB.5..h|discretizedHEX1.thermalElementA.1..h|discretizedHEX1.thermalElementA.2..h|discretizedHEX1.thermalElementA.3..h|discretizedHEX1.thermalElementA.4..h|discretizedHEX1.thermalElementA.5..h|discretizedHEX1.thermalElementB.1..h|discretizedHEX1.thermalElementB.2..h|discretizedHEX1.thermalElementB.3..h|discretizedHEX1.thermalElementB.4..h|discretizedHEX1.thermalElementB.5..h|firstOrder.y|receiver.M|receiver.U_med|twoPhaseSensorSelect.value|twoPhaseSensorSelect1.value|valveCompressorInletHeating.inlet.m_flow",fileNamePrefix="ThermofluidStream_ThermofluidStream.Examples.ReverseHeatPump",simflags="-alarm=1200 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Boundaries/PhaseSeparator.mo:41:3-41:139:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((accumulator.x >= 0.0 and accumulator.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= accumulator.x <= 1.0, has value: 1.28665" LOG_ASSERT | debug | Solving non-linear system 2665 failed at time=12.6188649946245. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 12.089461. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 12.023286. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | debug | Solving non-linear system 2718 failed at time=12.0232855606414. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 71.600000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "In "ReverseHeatPump.valveCompressorOutletCooling": Actuator signal out of valid range [0,1]" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 7 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 3501 steps taken LOG_STATS | info | | 5474 calls of functionODE LOG_STATS | info | | 630 evaluations of jacobian LOG_STATS | info | | 312 error test failures LOG_STATS | info | | 9 convergence test failures LOG_STATS | info | | 351065 linear system solves LOG_SUCCESS | info | The simulation finished successfully.