startTime=0 stopTime=125 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.125 wasm-jit simulation: simulate(ThermofluidStream.Boundaries.Tests.PhaseSeperator,startTime=0,stopTime=125,tolerance=1e-06,numberOfIntervals=1000,outputFormat="mat",variableFilter="Time|accumulator.M|accumulator.U_med|accumulator.m_flow_in|accumulator.m_flow_out|receiver.M|receiver.U_med|receiver.m_flow_out|source.outlet.m_flow|timeTable.a|timeTable.b|timeTable.last|timeTable.nextEvent|timeTable.nextEventScaled",fileNamePrefix="ThermofluidStream_ThermofluidStream.Boundaries.Tests.PhaseSeperator",simflags="-alarm=1200 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance3.p_min >= 611.657 and flowResistance3.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance3.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance.p_min >= 611.657 and flowResistance.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance2.p_min >= 611.657 and flowResistance2.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance2.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance1.p_min >= 611.657 and flowResistance1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance1.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Boundaries/PhaseSeparator.mo:41:3-41:139:writable] | | | | The following assertion has been violated at time 26.250000 | | | | ((receiver.x >= 0.0 and receiver.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= receiver.x <= 1.0, has value: 1.36475" LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 43.1047. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 43.1047. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 43.1047. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Boundaries/PhaseSeparator.mo:41:3-41:139:writable] | | | | The following assertion has been violated at time 38.625000 | | | | ((accumulator.x >= 0.0 and accumulator.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= accumulator.x <= 1.0, has value: 1.1942" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Boundaries/Internal/PartialVolume.mo:115:3-115:141:writable] | | | | The following assertion has been violated at time 75.250000 | | | | ((flowResistance.inlet.m_flow > receiver.m_flow_assert)) --> "In "PhaseSeperator.receiver": Positive mass flow rate at Volume outlet" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 16 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 2619 steps taken LOG_STATS | info | | 3979 calls of functionODE LOG_STATS | info | | 605 evaluations of jacobian LOG_STATS | info | | 180 error test failures LOG_STATS | info | | 23 convergence test failures LOG_STATS | info | | 50980 linear system solves LOG_SUCCESS | info | The simulation finished successfully.