startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 wasm-jit simulation: simulate(ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump",simflags="-alarm=480 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:21:3-21:45:writable] | | | | The following assertion has been violated at time 203.600000 | | | | ((StaticCentrifugalPump1.hn >= 0.0)) --> "Variable violating min constraint: 0.0 <= StaticCentrifugalPump1.hn, has value: -5.23154e-24" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 3 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 98 steps taken LOG_STATS | info | | 78 calls of functionODE LOG_STATS | info | | 74 evaluations of jacobian LOG_STATS | info | | 0 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.