startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 wasm-jit simulation: simulate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3",simflags="-alarm=480 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/CentrifugalPump.mo:43:3-43:45:writable] | | | | The following assertion has been violated at time 212.800000 | | | | ((centrifugalPump1.hn >= 0.0)) --> "Variable violating min constraint: 0.0 <= centrifugalPump1.hn, has value: -0.00174059" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 3 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 2010 steps taken LOG_STATS | info | | 2182 calls of functionODE LOG_STATS | info | | 272 evaluations of jacobian LOG_STATS | info | | 182 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 12617 linear system solves LOG_SUCCESS | info | The simulation finished successfully.