startTime=1 stopTime=10 tolerance=1e-06 numberOfIntervals=2000 stepSize=0.0045 wasm-jit simulation: simulate(TAeZoSysPro.HeatTransfer.Functions.FreeConvection.Tests.vertical_plate_ASHRAE,startTime=1,stopTime=10,tolerance=1e-06,numberOfIntervals=2000,outputFormat="empty",variableFilter="",fileNamePrefix="TAeZoSysPro_TAeZoSysPro.HeatTransfer.Functions.FreeConvection.Tests.vertical_plate_ASHRAE",simflags="-alarm=480 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20:3-20:157:writable] | | | | the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: euler-wasm LOG_STATS | info | | 2000 steps taken LOG_STATS | info | | 0 calls of functionODE LOG_STATS | info | | 0 evaluations of jacobian LOG_STATS | info | | 0 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.