startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=1000 stepSize=7.2 wasm-jit simulation: simulate(TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner,startTime=0,stopTime=7200,tolerance=1e-06,numberOfIntervals=1000,outputFormat="empty",variableFilter="",fileNamePrefix="TAeZoSysPro_TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner",simflags="-alarm=480 -lv LOG_STATS") LOG_STDOUT | info | iteration to converge on Fview: 8 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:21:3-21:129:writable] | | | | the Rayleigh number > 10^12 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ceiling_ASHRAE.mo:49:5-49:136:writable] | | | | the Rayleigh number >1.5*10^9 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:54:5-54:129:writable] | | | | the Rayleigh number >10^9 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:48:5-48:136:writable] | | | | the Rayleigh number >1.5*10^9 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20:3-20:157:writable] | | | | the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/BasesClasses/FreeConvection_dT_decoupled.mo:20:3-20:70:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((wood_burner.convection_emitter.T_mean >= 273.15 and wood_burner.convection_emitter.T_mean <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= wood_burner.convection_emitter.T_mean <= 373.15, has value: 563.628" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 164 steps taken LOG_STATS | info | | 196 calls of functionODE LOG_STATS | info | | 41 evaluations of jacobian LOG_STATS | info | | 2 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.