Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Physiomodel_Physiomodel.Gases.IO_Bus.GasesAndElectrolytes_test_SI.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real [:1:1-1:33:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo): time 0.02806/0.02806, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary master/package.mo): time 0.03955/0.03955, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0004014/0.0004014, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.000504/0.000504, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.3888/0.3888, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo:10244:31-10244:43:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 160000000000 into a real Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo): time 0.08755/0.08755, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package Physiomodel with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package Physiolibrary with version 3.1.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary master/package.mo) Using package Chemical with version 2.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo) Running command: simulate(Physiomodel.Gases.IO_Bus.GasesAndElectrolytes_test_SI,startTime=0,stopTime=1e+06,tolerance=1e-05,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Physiomodel_Physiomodel.Gases.IO_Bus.GasesAndElectrolytes_test_SI",simflags="-alarm=240 -lv LOG_STATS") simulate(Physiomodel.Gases.IO_Bus.GasesAndElectrolytes_test_SI,startTime=0,stopTime=1e+06,tolerance=1e-05,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Physiomodel_Physiomodel.Gases.IO_Bus.GasesAndElectrolytes_test_SI",simflags="-alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 1.112e-06/1.112e-06, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 2.483e-05/2.594e-05, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo:18186:7-18186:41:writable] Error: Base class Physiolibrary.Types.IO_Bus not found in scope IO_Bus. Error: Class Physiomodel.Gases.IO_Bus.GasesAndElectrolytes_test_SI not found in scope . Notification: Performance of FrontEnd: time 0.001948/0.001974, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 900] [Calling sys.exit(0), Time elapsed: 1.6836476807948202]