startTime=0 stopTime=0.1 tolerance=0.0001 numberOfIntervals=5000 stepSize=2e-05 wasm-jit simulation: simulate(Modelica.Magnetic.FluxTubes.Examples.Hysteresis.SinglePhaseTransformerWithHysteresis2,startTime=0,stopTime=0.1,tolerance=0.0001,numberOfIntervals=5000,outputFormat="mat",variableFilter="time|transformer.core.B|transformer.core.MagRel|transformer.core.Hstat|transformer.winding1.i|transformer.winding2.i",fileNamePrefix="Modelica_trunk_Modelica.Magnetic.FluxTubes.Examples.Hysteresis.SinglePhaseTransformerWithHysteresis2",simflags="-alarm=480 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 83 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 7988 steps taken LOG_STATS | info | | 13580 calls of functionODE LOG_STATS | info | | 1572 evaluations of jacobian LOG_STATS | info | | 882 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 1 linear system solves LOG_SUCCESS | info | The simulation finished successfully.