startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=5050 stepSize=0.00039604 wasm-jit simulation: simulate(Modelica.Electrical.Analog.Examples.IdealTriacCircuit,startTime=0,stopTime=2,tolerance=1e-06,numberOfIntervals=5050,outputFormat="mat",variableFilter="time|idealTriac.capacitor.v|idealTriac.idealThyristor.off|idealTriac.idealThyristor1.off",fileNamePrefix="Modelica_4.0.0_Modelica.Electrical.Analog.Examples.IdealTriacCircuit",simflags="-alarm=480 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 24 state events LOG_STATS | info | | 8 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 836 steps taken LOG_STATS | info | | 1075 calls of functionODE LOG_STATS | info | | 501 evaluations of jacobian LOG_STATS | info | | 14 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.