startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=5082 stepSize=0.708383 wasm-jit simulation: simulate(Modelica.Fluid.Examples.AST_BatchPlant.BatchPlant_StandardWater,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=5082,outputFormat="mat",variableFilter="time|B1.level|B1.medium.h|B2.level|B2.medium.h|B3.level|B3.medium.h|B4.level|B4.medium.h|B5.level|B5.medium.h|B6.level|B6.medium.h|B7.level|B7.medium.h|P1.medium.h|P1.medium.p|P2.medium.h|P2.medium.p|pipeB1B2.mediums.1..h|pipeB1B2.mediums.1..p|pipeB1B2.mediums.2..h|pipeB1B2.mediums.2..p|pipePump1B1.mediums.1..h|pipePump1B1.mediums.1..p|pipePump1B1.mediums.2..h|pipePump1B1.mediums.2..p|pipePump2B2.mediums.1..h|pipePump2B2.mediums.1..p|pipePump2B2.mediums.2..h|pipePump2B2.mediums.2..p|volume4.medium.h|volume4.medium.p|volume5.medium.h|volume5.medium.p|B5.InnerTankBottom.1..m_flow_negative|B5.InnerTankSide.1..m_flow_negative|B5.InnerTankTop.1..m_flow_negative|P1_on.y|P2_on.y|controller.Transition1.enableFire|controller.Transition10.enableFire|controller.Transition11.enableFire|controller.Transition12.enableFire|controller.Transition13.enableFire|controller.Transition2.enableFire|controller.Transition3.enableFire|controller.Transition4.enableFire|controller.Transition5.enableFire|controller.Transition6.enableFire|controller.Transition7.enableFire|controller.Transition8.enableFire|controller.Transition9.enableFire|controller.TransitionWithSignal1.enableFire",fileNamePrefix="Modelica_3.2.3_Modelica.Fluid.Examples.AST_BatchPlant.BatchPlant_StandardWater",simflags="-alarm=480 -emit_protected -lv LOG_STATS") Simulation execution failed for model: Modelica.Fluid.Examples.AST_BatchPlant.BatchPlant_StandardWater LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:1027:9-1032:39:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipeB1B3.flowModel.m_flows[1] >= 0.0 and pipeB1B3.flowModel.m_flows[1] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pipeB1B3.flowModel.m_flows[1] <= 1e5, has value: -6.38378e-16" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:1027:9-1032:39:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipeB2B3.flowModel.m_flows[1] >= 0.0 and pipeB2B3.flowModel.m_flows[1] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pipeB2B3.flowModel.m_flows[1] <= 1e5, has value: -6.38378e-16" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 594.763491 | | | | ((B6.topPorts[1].m_flow >= 0.0 and B6.topPorts[1].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= B6.topPorts[1].m_flow <= 1e5, has value: -3.63514e-05" LOG_ASSERT | debug | Solving non-linear system 3643 failed at time=740.837521649887. | | | | For more information please use -lv LOG_NLS. LOG_ERROR | error | wasm-jit simulation failed: CodegenWasmJit: nonlinear system did not converge