startTime=0 stopTime=15 tolerance=1e-06 numberOfIntervals=75000 stepSize=0.0002 wasm-jit simulation: simulate(Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse.ThyristorBridge2Pulse_DC_Drive,startTime=0,stopTime=15,tolerance=1e-06,numberOfIntervals=75000,outputFormat="mat",variableFilter="time|dcpm.inertiaRotor.phi|dcpm.inertiaRotor.w|inductor.i|lMains.i|meanCurrent.x|meanVoltage.x|pulse2.twoPulse.filter.1..firstOrder.y|pulse2.twoPulse.filter.1..transferFunction.1..x_scaled.1.|pulse2.twoPulse.filter.1..transferFunction.2..x_scaled.1.|rootMeanSquareVoltage.mean.x|meanCurrent.y|meanVoltage.y|pulse2.twoPulse.timerNegative.1..entryTime|pulse2.twoPulse.timerPositive.1..entryTime|rectifier.thyristor_n1.off|rectifier.thyristor_n2.off|rectifier.thyristor_p1.off|rectifier.thyristor_p2.off|rootMeanSquareVoltage.mean.y",fileNamePrefix="Modelica_3.2.3_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse.ThyristorBridge2Pulse_DC_Drive",simflags="-alarm=480 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 6140 state events LOG_STATS | info | | 1500 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 232473 steps taken LOG_STATS | info | | 303260 calls of functionODE LOG_STATS | info | | 85314 evaluations of jacobian LOG_STATS | info | | 2655 error test failures LOG_STATS | info | | 1 convergence test failures LOG_STATS | info | | 1504744 linear system solves LOG_SUCCESS | info | The simulation finished successfully.