startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=5004 stepSize=0.0019984 wasm-jit simulation: simulate(ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpRecirculation,startTime=0,stopTime=10,tolerance=1e-06,numberOfIntervals=5004,outputFormat="mat",variableFilter="time|pump.medium.T|N_pump.y|Source.ports.1..m_flow|Source.ports.1..p|Source.ports.1..h_outflow|Sink.ports.1..m_flow|Sink.ports.1..p|Sink.ports.1..h_outflow|pump.port_b.m_flow|pump.port_b.p|pump.port_b.h_outflow|V1.port_b.m_flow|V1.port_b.p|V1.port_b.h_outflow|V1.minLimiter.y|V2.port_b.m_flow|V2.port_b.p|V2.port_b.h_outflow|V2.minLimiter.y|V1_Opening.y|V2_Opening.y",fileNamePrefix="ModelicaTest_4.1.0_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpRecirculation",simflags="-alarm=480 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 6 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 193 steps taken LOG_STATS | info | | 248 calls of functionODE LOG_STATS | info | | 131 evaluations of jacobian LOG_STATS | info | | 5 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 1 linear system solves LOG_SUCCESS | info | The simulation finished successfully.