startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=2500 stepSize=4 wasm-jit simulation: simulate(IDEAS.Fluid.HeatPumps.Examples.HeatPump_perfFromTout,startTime=0,stopTime=10000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.HeatPumps.Examples.HeatPump_perfFromTout",simflags="-alarm=480 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump3.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump3: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump4.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump4: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump5.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump5: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump6.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump6: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump7.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump7: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 837 steps taken LOG_STATS | info | | 1294 calls of functionODE LOG_STATS | info | | 220 evaluations of jacobian LOG_STATS | info | | 100 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.