Dynawo_dev test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
106 54 54 54 54 54 52 38

Test started: 2026-11-12 01:14:45
Total time taken: 0:09:12
System info: ryzen-9950x: AMD Ryzen 9 9950X3D 16-Core Processor, 124 GB RAM, Ubuntu 26.04.1 LTS

OpenModelica Version: v1.28.0-dev.1869+gcc15e9634d.rust
OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
1c9738a2026-11-11 20:56:15 +0100Martin SjölundInstall a newer nightly omc in the testing image (#415)

Tested Library: Dynawo_dev 2.0.0

{
 "path": "dynawo/sources/Models/Modelica/Dynawo",
 "sha": "2a7612267f630c5ecc3758b8d402c508216c30b5",
 "support": "noSupport",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "2.0.0-master",
 "wasm": {
  "2": {
   "generation": 1,
   "sha256": "abfbc4c7a83c7af72886aaa5d6f45e8ba409aa42ebc1baaf61a508a7514eb350",
   "systemLibraries": [
    "libc"
   ],
   "zipfile": "https://libraries.openmodelica.org/precompiled/wasm32-wasip1/omc-1/Dynawo-wasm32-wasip1-4eb0d74d63821cf7.zip"
  }
 },
 "zipfile": "https://github.com/dynawo/dynawo/archive/2a7612267f630c5ecc3758b8d402c508216c30b5.zip"
}

BuildModel time limit: 660s
Simulation time limit: 240s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Reference Files: https://github.com/dynawo/dynawo (2a7612267f630c5ecc3758b8d402c508216c30b5)

CommitDateAuthorSummary
2a7612267f62026-10-19 16:31:21 +0200GOTTARDO Pietro (Externe)#3152 GFM models

Verified using: v1.28.0-dev.1860+ge89ef0a.cmake (diffSimulationResults)

Flags:
setCommandLineOptions("--simCodeTarget=wasm-jit")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
setCommandLineOptions("--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext");
Config:
{
 "extraCustomCommands": [
  "setCommandLineOptions(\"--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext\");"
 ],
 "library": "Dynawo",
 "libraryVersion": "master",
 "libraryVersionNameForTests": "dev",
 "referenceFileExtension": "csv",
 "referenceFileNameDelimiter": ".",
 "referenceFiles": {
  "destination": "ReferenceFiles/Dynawo",
  "git-directory": "dynawo/sources/Models/Modelica/Dynawo/Examples/references",
  "giturl": "https://github.com/dynawo/dynawo"
 },
 "referenceFinalDot": "_res."
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
Dynawo.Examples.BESS.WECC.BESSCurrentSource 0.000.060.480.060.000.000.000.001.37
Dynawo.Examples.BESS.WECC.BESSCurrentSourceExternalPCS 0.000.070.400.070.000.000.000.001.28
Dynawo.Examples.BESS.WECC.BESSCurrentSourceNoPPC 0.000.040.260.040.000.000.000.001.05
Dynawo.Examples.ENTSOE.TestCase1 0.000.040.280.040.000.000.000.001.08
Dynawo.Examples.ENTSOE.TestCase2 0.000.030.230.030.000.000.000.001.04
Dynawo.Examples.ENTSOE.TestCase3 0.000.030.220.030.000.000.000.001.05
Dynawo.Examples.GridCodeSimulations.RunSimulations 0.000.480.210.480.000.000.000.001.45
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xcca 0.000.150.220.150.000.000.000.001.03
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xccb 0.000.120.220.120.000.000.000.001.07
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI5 0.000.120.270.120.000.000.000.001.07
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI6 0.000.090.300.090.000.000.000.001.08
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMax 0.000.080.230.080.000.000.000.001.08
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMin 0.000.110.240.110.000.000.000.001.05
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10 0.000.090.260.090.000.000.000.001.14
Dynawo.Examples.GridForming.Droop.DynGFMDroopSmib (sim)0.00 (2 verified)0.400.220.250.050.080.010.010.071.50
Dynawo.Examples.GridForming.EpriSmib (sim)0.00 (1/4 failed)0.040.300.210.060.070.010.010.141.19
Dynawo.Examples.GridForming.GridForming (sim)0.00 (10 verified)1.640.510.250.090.240.030.020.123.25
Dynawo.Examples.GridForming.PlantControl.DynGFMCCPlantControl (sim)0.01 (1/2 failed)0.100.610.310.260.150.020.010.171.81
Dynawo.Examples.GridForming.PlantControl.DynGFMDroopPlantControl (sim)0.00 (2 verified)0.100.540.260.250.140.030.010.101.54
Dynawo.Examples.GridForming.PlantControl.DynGFMVSMPlantControl (sim)0.01 (1/2 failed)0.120.580.240.250.140.030.010.151.60
Dynawo.Examples.GridForming.Tests.NodeFault.CCVSM (sim)0.03 (2 verified)1.620.240.180.040.060.010.010.112.73
Dynawo.Examples.GridForming.Tests.NodeFault.Droop (sim)0.09 (2 verified)59.790.220.190.060.070.010.010.0761.02
Dynawo.Examples.GridForming.Tests.NodeFault.VSM (sim)0.03 (2 verified)2.230.210.170.050.060.010.010.073.28
Dynawo.Examples.GridForming.Tests.RoCoF.CCVSM (sim)0.03 (2 verified)0.630.210.200.070.060.010.010.061.74
Dynawo.Examples.GridForming.Tests.RoCoF.Droop (sim)0.04 (1/2 failed)59.090.220.230.040.100.010.010.0660.30
Dynawo.Examples.GridForming.Tests.RoCoF.VSM (sim)0.03 (2 verified)0.720.230.210.040.110.010.010.061.87
Dynawo.Examples.GridForming.Tests.SCRJump.CCVSMDown (sim)0.03 (2 verified)0.990.230.170.050.070.010.010.082.04
Dynawo.Examples.GridForming.Tests.SCRJump.CCVSMUp (sim)0.03 (2 verified)0.700.260.200.090.070.010.010.081.92
Dynawo.Examples.GridForming.Tests.SCRJump.DroopDown (sim)0.05 (2 verified)73.870.220.190.050.070.010.010.0875.02
Dynawo.Examples.GridForming.Tests.SCRJump.DroopUp (sim)0.04 (2 verified)51.630.220.190.040.070.010.010.0952.82
Dynawo.Examples.GridForming.Tests.SCRJump.VSMDown (sim)0.05 (2 verified)1.110.220.190.040.070.010.010.082.26
Dynawo.Examples.GridForming.Tests.SCRJump.VSMUp (sim)0.03 (2 verified)0.720.250.190.060.080.010.010.101.82
Dynawo.Examples.GridForming.Tests.VoltageAngleJump.CCVSM (sim)0.03 (2 verified)0.490.260.220.040.060.010.010.141.63
Dynawo.Examples.GridForming.Tests.VoltageAngleJump.Droop (sim)0.03 (2 verified)0.760.190.180.060.060.010.010.061.85
Dynawo.Examples.GridForming.Tests.VoltageAngleJump.VSM (sim)0.03 (2 verified)0.710.190.200.040.070.010.010.071.88
Dynawo.Examples.GridForming.Tests.VoltageMagnitudeJump.CCVSM (sim)0.06 (2 verified)0.230.230.180.060.060.010.010.081.44
Dynawo.Examples.GridForming.Tests.VoltageMagnitudeJump.Droop (sim)0.03 (2 verified)0.230.200.200.050.060.010.010.071.29
Dynawo.Examples.GridForming.Tests.VoltageMagnitudeJump.VSM (sim)0.03 (2 verified)0.200.190.220.040.060.010.010.061.33
Dynawo.Examples.GridForming.VSM.DynGFMCCVSMSmib (sim)0.05 (2 verified)0.560.210.170.040.060.010.010.081.58
Dynawo.Examples.GridForming.VSM.DynGFMVSMSmib (sim)0.03 (2 verified)1.100.220.160.040.070.010.010.102.18
Dynawo.Examples.GridForming.VSM.DynGFMVSMSmibConvPLL (sim)0.01 (2 verified)0.650.170.230.040.060.010.010.051.75
Dynawo.Examples.HVDC.HVDC 0.000.050.200.050.000.000.000.001.07
Dynawo.Examples.IEEE14.TestCases.IEEE14CLA 0.000.050.210.050.000.000.000.000.93
Dynawo.Examples.IEEE14.TestCases.IEEE14DisconnectLine 0.000.060.190.060.000.000.000.000.89
Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent 0.000.050.170.050.000.000.000.000.88
Dynawo.Examples.IEEE57.TestCases.IEEE57DisconnectLine 0.000.170.220.170.000.000.000.000.97
Dynawo.Examples.IEEE57.TestCases.IEEE57HvdcPsDisconnectLine 0.000.200.240.200.000.000.000.001.04
Dynawo.Examples.IEEE57.TestCases.IEEE57NoEvent 0.000.150.190.150.000.000.000.000.92
Dynawo.Examples.IEEE118.TestCases.IEEE118NoEvent 0.000.570.230.570.000.000.000.001.39
Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl (sim)0.00 (7 verified)0.010.110.230.020.030.010.010.051.06
Dynawo.Examples.IllustrativeExamples.DynaFlow.PhaseShifterTransformer 0.000.010.190.010.000.000.000.000.86
Dynawo.Examples.InertialGrid.DoubleInertialGrid (sim)0.01 (2 verified)0.530.160.270.020.060.010.010.061.53
Dynawo.Examples.LoadFrequencyDependent.LoadAlphaBetaFrequencyDependent (sim)0.00 (2/3 failed)0.010.110.200.010.030.000.000.060.89
Dynawo.Examples.LoadFrequencyDependent.LoadZIPFrequencyDependent (sim)0.01 (3 verified)0.010.110.180.020.040.000.000.050.95
Dynawo.Examples.Nordic.TestCases.LoadFlow (sim)0.01 (7 verified)0.011.840.200.401.000.090.070.292.71
Dynawo.Examples.Nordic.TestCases.TestCase 0.000.790.220.790.000.000.000.001.67
Dynawo.Examples.Photovoltaics.WECC.PVCurrentSource 0.000.070.220.070.000.000.000.001.05
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource2 0.000.060.230.060.000.000.000.000.92
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource4 0.000.050.180.050.000.000.000.000.90
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSourceNoPPC 0.000.040.190.040.000.000.000.000.92
Dynawo.Examples.RVS.TestCases.LoadFlow (sim)0.00 (4/7 failed)7.901.880.210.331.000.100.080.3610.63
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadNoRestorative 0.000.930.170.930.000.000.000.001.72
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadRestorative 0.001.000.171.000.000.000.000.001.78
Dynawo.Examples.RVS.TestCases.TestA.TestAShuntNoRestorative 0.000.940.200.940.000.000.000.001.70
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcLoadReset 0.000.940.180.940.000.000.000.001.69
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcNoLoadReset 0.000.880.200.880.000.000.000.001.71
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcLoadReset 0.000.930.180.930.000.000.000.001.76
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcNoLoadReset 0.000.950.180.950.000.000.000.001.89
Dynawo.Examples.SMIB.SMIBStepEfdPm 0.000.020.230.020.000.000.000.000.96
Dynawo.Examples.SMIB.SMIBStepPm 0.000.030.270.030.000.000.000.001.00
Dynawo.Examples.SMIB.Standard.GovCt2St4b 0.000.030.170.030.000.000.000.000.80
Dynawo.Examples.SMIB.Standard.GovHydro4St4b 0.000.030.190.030.000.000.000.000.91
Dynawo.Examples.SMIB.Standard.GovSteam1St4b2 0.000.030.190.030.000.000.000.000.91
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1 0.000.030.190.030.000.000.000.000.88
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3 0.000.030.210.030.000.000.000.000.90
Dynawo.Examples.SMIB.Standard.GovSteamEuSt4b 0.000.040.190.040.000.000.000.000.90
Dynawo.Examples.SVarC.SVarCFaultImp (sim)0.00 (1/3 failed)0.010.090.230.030.020.000.000.031.02
Dynawo.Examples.SVarC.SVarCLoadVarQ (sim)0.00 (3 verified)0.010.090.210.020.030.000.000.030.98
Dynawo.Examples.SVarC.SVarCLoadVarQLarge (sim)0.03 (3 verified)0.010.100.210.030.030.000.000.031.00
Dynawo.Examples.SVarC.SVarCModeChange (sim)0.00 (1/3 failed)0.010.070.190.020.020.000.000.030.84
Dynawo.Examples.SVarC.SVarCStepURef (sim)0.01 (2 verified)0.010.110.220.020.020.000.000.060.97
Dynawo.Examples.SystemFrequencyResponse.ReducedOrderSFR (sim)0.01 (1/2 failed)0.010.030.200.010.000.000.000.010.87
Dynawo.Examples.SystemFrequencyResponse.SimplifiedSFR (sim)0.00 (2 verified)0.010.040.210.000.010.000.000.020.84
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2015 (sim)0.02 (3/4 failed)0.260.850.260.230.320.040.040.222.12
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020 (sim)0.03 (3/4 failed)0.300.990.290.290.340.050.050.272.41
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020FOCB (sim)0.08 (2/4 failed)1.520.970.210.240.330.060.060.273.82
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020UDip (sim) 145.140.970.250.250.330.060.060.27147.88
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020 (sim)0.13 (3/4 failed)2.170.870.180.190.320.050.040.264.37
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020FOCB (sim)0.10 (3/4 failed)1.210.880.190.190.320.060.040.263.22
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015 (sim)0.01 (3 verified)0.180.540.200.110.210.030.020.171.63
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB (sim)0.01 (3 verified)0.130.550.180.110.210.030.020.181.58
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020 (sim)0.03 (4 verified)0.190.600.180.120.210.030.030.211.66
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020FOCB (sim)0.01 (4 verified)0.140.590.200.140.200.030.030.201.60
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015 (sim)0.01 (3 verified)0.200.570.210.130.220.030.020.171.63
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015FOCB (sim)0.01 (3 verified)0.130.550.160.120.220.030.020.171.57
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020 (sim)0.01 (4 verified)0.260.580.180.120.210.030.020.201.71
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020FOCB (sim) 0.070.600.160.110.210.030.020.221.42
Dynawo.Examples.Wind.WECC.WT3CurrentSource1 0.000.040.230.040.000.000.000.000.94
Dynawo.Examples.Wind.WECC.WT3CurrentSource2 0.000.060.210.060.000.000.000.000.97
Dynawo.Examples.Wind.WECC.WT4ACurrentSource 0.000.040.190.040.000.000.000.000.99
Dynawo.Examples.Wind.WECC.WT4BCurrentSource 0.000.030.190.030.000.000.000.001.05
Dynawo.Examples.Wind.WECC.WTG3CurrentSource1 0.000.080.200.080.000.000.000.001.01
Dynawo.Examples.Wind.WECC.WTG3CurrentSource2 0.000.080.180.080.000.000.000.001.05
Dynawo.Examples.Wind.WECC.WTG4ACurrentSource 0.000.070.170.070.000.000.000.001.04
Dynawo.Examples.Wind.WECC.WTG4BCurrentSource 0.000.050.180.050.000.000.000.000.95
Dynawo.Examples.Wind.WECC.WTG4BCurrentSourceExternalPCS 0.000.050.180.050.000.000.000.001.05